Blizzard Lighting, LLC www.blizzardlighting.
TABLE OF CONTENTS Flurry™ TRI 1 1. Getting Started 3 What’s In The Box? Getting It Out Of The Box Powering Up! Getting A Hold Of Us Safety Instructions (Don’t Stick Your Hand In The Toaster!) 2. Meet The Flurry™ TRI 5 Features DMX Quick Reference (13-Channel Mode) DMX Quick Reference (5-Channel Mode) The Flurry Pin-up Picture 5 5 6 6 3.
1. GETTING STARTED What’s In The Box? • • • • • 1 x Flurry™ TRI An Ever-So-Handy Power Cord A Sweet DMX Cable A Totally Useful Mounting Bracket This Lovely User Manual Getting It Out Of The Box Congratulations on purchasing one of the niftiest little moving lights this side of anywhere! Now that you’ve got your Flurry (or hopefully, Flurries), you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition.
SAFETY INSTRUCTIONS • Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide. • ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture. • This product is intended for indoor use only. • To prevent risk of fire or shock, do not expose fixture to rain or moisture.
2.
DMX Quick Reference (5-Channel Mode) Channel What It Does 1 Pan 2 Tilt 3 Dimmer & Strobe 4 Color Macros 5 Reserved Figure 1: The Flurry Pin-Up Picture High Power LED’s Head LED Readout Control Panel Figure 2: The Rear Connections DMX In AC Power DMX Out Fuse Cover 110V/220V Switch Flurry TRI Manual Rev.
3. SETUP Fuse Replacement With a flat head screwdriver, wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power. Connecting A Bunch of Flurry™ TRI Lumieres You will need a serial data link to run light shows using a DMX-512 controller or to run shows on two or more fixtures set to sync in master/slave operating mode.
Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end. (Duh!) CAUTION: Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
Fixture Linking (Master/Slave Mode) 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
4. OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with the Flurry™ TRI are accessed by using the control panel on the front of the fixture. There are 4 control buttons below the LED display which allow you to navigate through the various control panel menus. Is used to initially access the control panel system, and also navigate to the previous higher-level menu item. Scrolls through menu items and numbers in ascending order.
Control Panel Menu Structure Flurry TRI Manual Rev.
Additional User Adjustments TO SET THE PAN TO REVERSED OR NORMAL: 1.) Press the button until it shows or 2.) Use the buttons to set to the desired position, press to confirm. TO SET THE TILT TO REVERSED OR NORMAL: or 1.) Press the button until it shows 2.) Use the buttons to set to the desired position, press to confirm. TO SET THE LED READOUT TO REVERSED OR NORMAL: 1.) Press the button until it shows or 2.
Stand-Alone Mode (Auto Mode): Allows a single unit to run to a factory installed program at one of two speeds. 1.) To set the fixture in auto mode fast, select Once confirmed the display reads . . 2.) To set the fixture in auto mode Slow, select . . Once confirmed the display reads Master/Slave Mode (Auto or Sound Active): Allows you to link up to 32 units together without a controller. 1.) Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units.
DMX Channel Values (13 Channel Mode) Channel Channel Value Does...
DMX Channel Values (5 Channel Mode) Channel Channel Value Does...
Troubleshooting Symptom Solution Fixture AutoShut Off Check the fan in the fixture. If it is stopped or moving slower than normal, the unit may have shut itself off due to high heat. This is to protect the fixture from overheating. Clear the fan of obstructions, or return the unit for service. Beam is Dim Check optical system and clean excess dust/grime. Also ensure that the 220V/110V switch is in the correct position, if applicable.
5. APPENDIX A Quick Lesson On DMX DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre Technology (USITT) as a standardized method for connecting lighting consoles to lighting dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility. The Entertainment Services and Technology Association (ESTA) has since assumed control over the DMX512 standard. It has also been approved and recognized for ANSI standard classification.
Keeping Your Flurry As Good As New The fixture you’ve received is a rugged, tough piece of pro lighting equipment, and as long as you take care of it, it will take care of you. That said, like anything, you’ll need to take care of it if you want it to operate as designed. You should absolutely keep the fixture clean, especially if you are using it in an environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled drinks.
Tech Specs! Weight & Dimensions Length 6.8 inches (173 mm) Width 6.8 inches (173 mm) Height 9.8 inches (249 mm) Weight 6.7 lbs (3.8 kg) Power Operating Voltage 110-230VAC, 50-60 Hertz (autoranging) Fuse 2A 250V Power Consumption 120W Light Source LED 18x3W (TRI-Color), 100,000 hours, Edison® Brand. Optical Beam Angle 18 degrees Luminous Intensity 12,110 (full white) lux/1m Movement Range Pan 540 degrees Tilt 270 degrees Thermal Max. Operating Temp.
Enjoy your product! Our sincerest thanks for your purchase! --The team @ Blizzard Lighting