Blizzard Lighting, LLC www.blizzardlighting.
TABLE OF CONTENTS ROCKLITE™ RAYGUN LED 1 1. Getting Started 3 What’s In The Box? Getting It Out Of The Box Powering Up! Getting A Hold Of Us Safety Instructions (Don’t Stick Your Hand In The Toaster!) 3 3 3 3 4 2. Meet The ROCKLITE™ RAYGUN LED 5 Features DMX Quick Reference The RAYGUN™ Pin-up Picture 5 5 6 3.
1. GETTING STARTED What’s In The Box? • 1x ROCKLITE™ RAYGUN™ LED Very Narrow Spot LED Fixture • This Lovely User Manual Getting It Out Of The Box Congratulations on purchasing The ROCKLITE™ RAYGUN™! You’ll now be able to repel any alien takeover while headbanging your permed mullet well into the wee hours of the morning! Well, now that you’ve got your RAYGUN™ (or hopefully, RAYGUNs!), You should carefully unpack the box and check the contents to ensure that all parts are present and in good condition.
SAFETY INSTRUCTIONS • Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide. • ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture. • This product is intended for indoor use only. • To prevent risk of fire or shock, do not expose fixture to rain or moisture.
2.
Figure 1: The RAYGUN™ Pin-Up Picture “The Business End” -- LargeScale Collimating Lens Heavy-Gauge Spun Aluminum Enclosure Mounting Yokes & Adjustment/Locking Knobs Figure 2: The Rear Connections LED Control Panel Grounding Screw DMX In ROCKLITE RAYGUN Manual Rev.
3. SETUP Fuse Replacement CAUTION! The ROCKLITE™ RAYGUN utilizes a high-output switchmode power supply with an internal fuse. Under normal operating conditions, the fuse should not require replacement. The fuse is field replaceable, however it is an advanced procedure suited to qualified individuals. Should your ROCKLITE™ fuse require replacement, please contact Blizzard Lighting for instructions, or to return your unit for service.
Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end. (Duh!) CAUTION: Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
Fixture Linking (Master/Slave Mode) 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
4. OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with the ROCKLITE™ LED are accessed by using the control panel on the rear of the fixture. There are 4 control buttons below the LED display which allow you to navigate through the various control panel menus.
Control Panel Menu Structure A001 3CH 5CH A001 - A512 Soud RuN0 RuN1 RuN2 L000 P000 LEoN Soud RuN0 RuN1 RuN2 L000-L255 P000-P255 LEoN - LoFF ROCKLITE RAYGUN Manual Rev.
DMX Mode Allows the unit to be controlled by any universal DMX controller in one of 2 channel modes. 1.) The default mode for the fixture is DMX, which appears as Readout. A001 on the LED 2.) To select the DMX personality (channel mode), select either 3 Ch (3-Chan- 5 Ch (5-Channel Mode), then hit to confirm. nel Mode), or 3.) Then, use the buttons to select the correct address between A001-A512, then hit to confirm.
DMX Values In-Depth (3 & 5-Channel Mode) Channel 1 2 3 4 5 Value 000 008 016 032 048 064 080 112 129 193 <--> <--> <--> <--> <--> <--> <--> <--> <--> <--> What It Does (3 Ch.) 007 015 031 047 063 079 111 128 192 255 What It Does (5 Ch.
Troubleshooting Symptom Solution Fixture AutoShut Off Check the fan in the fixture. If it is stopped or moving slower than normal, the unit may have shut itself off due to high heat. This is to protect the fixture from overheating. Clear the fan of obstructions, or return the unit for service. Beam is Dim Check optical system and clean excess dust/grime. Also ensure that the 220V/110V switch is in the correct position, if applicable.
5. APPENDIX A Quick Lesson On DMX DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre Technology (USITT) as a standardized method for connecting lighting consoles to lighting dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility. The Entertainment Services and Technology Association (ESTA) has since assumed control over the DMX512 standard. It has also been approved and recognized for ANSI standard classification.
Keeping Your ROCKLITE™ As Good As New The fixture you’ve received is a rugged, tough piece of pro lighting equipment, and as long as you take care of it, it will take care of you. That said, like anything, you’ll need to take care of it if you want it to operate as designed. You should absolutely keep the fixture clean, especially if you are using it in an environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled drinks.
Tech Specs! Weight & Dimensions Length 14.25 inches (360 mm) Width 11 inches (278 mm) Height 7.75 inches (197 mm) Weight 7.2 lbs (3.25 kg) Power Operating Voltage 90-230VAC, 50-60 Hertz, Autoranging Fuse 3A 250V 30W @ 120VAC Power Consumption .35A Operating, .32A Inrush Power Factor: .66 Light Source LED 50-watt Luminus CBT-90 White LED, 6,500 Color Temperature, 50,000 Hours Optical Beam Angle 2.5 degree Luminous Intensity 28,220 Lux @ 1m 13,180 Lux @ 2m Thermal Max. Operating Temp.
This page intentionally left blank. ROCKLITE RAYGUN Manual Rev.
This page intentionally left blank.
Enjoy your product! Our sincerest thanks for your purchase! --The team @ Blizzard Lighting