Blizzard Lighting, LLC www.blizzardlighting.
TABLE OF CONTENTS Q-Stick™ RGBW LED 1 1. Getting Started 3 What’s In The Box? Getting It Out Of The Box Powering Up! Getting A Hold Of Us Safety Instructions (Don’t Stick Your Hand In The Toaster!) 2. Meet The Q-Stick™ RGBW LED 5 Features DMX Quick Reference The Q-Stick™ Pin-up Picture 5 5 6 3.
1. GETTING STARTED What’s In The Box? • 1 x Q-Stick™ RGBW Professional LED PAR Fixture • This Lovely User Manual Getting It Out Of The Box Congratulations on quite a fine purchase! You’re the quintessential quick-witted lighting guy/gal which everyone always re-Quests! (“Q” words, get it?) Now that you’ve got your Q-Stick™ (or hopefully, QSticks), you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition.
SAFETY INSTRUCTIONS • Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide. • ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture. • This product is intended for indoor use only. • To prevent risk of fire or shock, do not expose fixture to rain or moisture.
2.
Figure 1: The Q-Stick™ Pin-Up Picture High Power 4-in-1 LEDs Mounting Yoke & Adjustment/ Locking Knobs Sturdy metal enclosure Figure 2: The Rear Connections Fan Guard POWERCON In POWERCON Out LED Control Panel 3-Pin & 5-Pin DMX In Q-Stick™ RGBW Manual Rev.
3. SETUP Fuse Replacement With a flat head screwdriver, wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power. Connecting A Bunch of Q-Sticks™ You will need a serial data link to run light shows using a DMX-512 controller or to run shows on two or more fixtures set to sync in master/slave operating mode.
Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end. (Duh!) CAUTION: Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
Fixture Linking (Master/Slave Mode) 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
4. OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with the Q-Stick™ LED are accessed by using the control panel on the rear of the fixture. There are 4 control buttons below the LED display which allow you to navigate through the various control panel menus.
Control Panel Menu Structure Addr F.001 - F511 P.001 - P511 A.001 - A511 cH-- F.001 P.001 A.001 rL-GL-bL-EL-- r000- r100 G000- G100 b000- b100 E000- U100 FAdE 000-100 FLAS 000-100 ASC- 000-100 AuTo 000-100 Q-Stick™ RGBW Manual Rev.
DMX Mode Allows the unit to be controlled by any universal DMX controller. 1.) The default mode for the fixture is DMX, which appears as either F/P/A/.001 on the LED Readout, depending on the channel mode. To select a different DMX address, using the
Manual Color Adjustment: Allows the user to adjust the color balance of the fixture. These settings are global, they will effect all modes. 1.) Use the
Troubleshooting Symptom Solution Fixture AutoShut Off Check the fan in the fixture. If it is stopped or moving slower than normal, the unit may have shut itself off due to high heat. This is to protect the fixture from overheating. Clear the fan of obstructions, or return the unit for service. Beam is Dim Check optical system and clean excess dust/grime. Also ensure that the 220V/110V switch is in the correct position, if applicable.
5. APPENDIX A Quick Lesson On DMX DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre Technology (USITT) as a standardized method for connecting lighting consoles to lighting dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility. The Entertainment Services and Technology Association (ESTA) has since assumed control over the DMX512 standard. It has also been approved and recognized for ANSI standard classification.
Keeping Your Q-Stick™ As Good As New The fixture you’ve received is a rugged, tough piece of pro lighting equipment, and as long as you take care of it, it will take care of you. That said, like anything, you’ll need to take care of it if you want it to operate as designed. You should absolutely keep the fixture clean, especially if you are using it in an environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled drinks.
Tech Specs! Weight & Dimensions Length 21.25 inches (550 mm) Width 5 inches (127 mm) Height 2.5 inches (63 mm) Weight 6.7 lbs (3 kg) Power Operating Voltage 90-230VAC, 50-60 Hertz Fuse 3A 250V 52W Power Consumption .65A, .39 Inrush Power Factor: .66 Light Source LED 9x Quad-Color (4-in-1) 10-watt RGBW LEDs 60,000 hours. Optical Beam Angle 25 degree optics standard 25 degree beam 29 degree field Luminous Intensity 6,200 Lux @ 1m 2,550 Lux @ 2m Thermal Max. Operating Temp.
This page intentionally left blank. Q-Stick™ RGBW Manual Rev.
This page intentionally left blank.
Enjoy your product! Our sincerest thanks for your purchase! --The team @ Blizzard Lighting