Owner manual
Page 16
ToughSTICK™ RGBAW Manual - Rev. C Copyright (c) 2012 Blizzard Lighting, LLC
Troubleshooting
Symptom Solution
Fixture Auto-
Shut Off
Checkthefaninthexture.Ifitisstoppedormoving
slower than normal, the unit may have shut itself off due to
highheat.Thisistoprotectthexturefromoverheating.
Clear the fan of obstructions, or return the unit for service.
Beam is Dim Check optical system and clean excess dust/grime. Also
ensure that the 220V/110V switch is in the correct position,
if applicable.
No Light Output Checktoensurextureisoperatingundercorrectmode,
IEauto/DMX/Etc.,ifapplicable.Contactserviceformore
information.
Chase Speed
Too Fast/Slow
Check to ensure proper setup of speed adjustment.
No Power Check fuse, AC cord and circuit for malfunction.
Blown Fuse Check AC cord and circuit for damage, verify that moving
parts are not restricted and that unit’s ventilation is not
obstructed
Slow Movement Verify that 220V/110V switch is in the correct position, if
applicable. Also check that speed channels are set appro-
priately.
Fixture Not
Responding /
RespondingEr-
raticly
Make sure all connectors are seated properly and securely.
Use Only DMX Cables.
Install a Terminator.
Check all cables for defects.
Resetxture(s).
If your problem isn’t listed, or if problems persist,
please contact support: support@blizzardlighting.com.