User guide
Page 7
ToughPAR Zoom RGBAW Manual Rev. A Copyright (c) 2013 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
CAUTION! The ToughPAR™ Zoom RGBAW utilizes a high-output switch-
mode power supply with an internal fuse. Under normal operating
conditions,thefuseshouldnotrequirereplacement.Thefuseiseld
replaceable,howeveritisanadvancedproceduresuitedtoqualied
individuals.ShouldyourToughPAR™ZoomRGBAWfuserequire
replacement, please contact Blizzard Lighting for instructions, or to return
your unit for service.
Connecting A Bunch of ToughPAR™ Zoom RGBAW Fixtures
You will need a serial data link to run light shows using a DMX-512
controllerortorunshowsontwoormorexturessettosyncinmaster/
slaveoperatingmode.Thecombinednumberofchannelsrequiredbyall
thexturesonaserialdatalinkdeterminesthenumberofxturesthe
data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also,connectingmorethan32xturesononeserialdatalinkwithoutthe
use of a DMX optically-isolated splitter may result in deterioration of the
digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640 ft).
Themaximumrecommendednumberofxturesonaserialdatalinkis32
xtures.
Data/DMX Cabling
Tolinkxturestogetheryou’llneeddatacables.Youshouldusedata-
gradecablesthatcancarryahighqualitysignalandarelessproneto
electromagnetic interference.
Forinstance,Belden©9841meetsthespecicationsforEIARS-485
applications. Standard microphone cables will “probably” be OK, but note
that they cannot transmit DMX data as reliably over long distances. In
any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms