ToughPAR Zoom RGBAW Manual Rev. A Copyright (c) 2013 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
CAUTION! The ToughPAR™ Zoom RGBAW utilizes a high-output switch-
mode power supply with an internal fuse. Under normal operating
conditions,thefuseshouldnotrequirereplacement.Thefuseiseld
replaceable,howeveritisanadvancedproceduresuitedtoqualied
individuals.ShouldyourToughPAR™ZoomRGBAWfuserequire
replacement, please contact Blizzard Lighting for instructions, or to return
your unit for service.
Connecting A Bunch of ToughPAR™ Zoom RGBAW Fixtures
You will need a serial data link to run light shows using a DMX-512
controllerortorunshowsontwoormorexturessettosyncinmaster/
slaveoperatingmode.Thecombinednumberofchannelsrequiredbyall
thexturesonaserialdatalinkdeterminesthenumberofxturesthe
data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also,connectingmorethan32xturesononeserialdatalinkwithoutthe
use of a DMX optically-isolated splitter may result in deterioration of the
digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640 ft).
Themaximumrecommendednumberofxturesonaserialdatalinkis32
xtures.
Data/DMX Cabling
Tolinkxturestogetheryou’llneeddatacables.Youshouldusedata-
gradecablesthatcancarryahighqualitysignalandarelessproneto
electromagnetic interference.
Forinstance,Belden©9841meetsthespecicationsforEIARS-485
applications. Standard microphone cables will “probably” be OK, but note
that they cannot transmit DMX data as reliably over long distances. In
any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms