HushPAR Theatrik Manual Rev. B © 2013-14 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
CAUTION! The HushPar™ Theatrik utilizes a high-output switch-mode power supply
with an internal fuse. Under normal operating conditions, the fuse should not require
replacement. The fuse is eld replaceable, however it is an advanced procedure suited
to qualied individuals. Should your HushPar™ Theatrik fuse require replacement, please
contact Blizzard Lighting for instructions, or to return your unit for service.
Mounting & Rigging
• Slide the barn door assembly into the grooves on the front of the xture. (optional)
• Securely connect the power cable to a power socket. Dimming can be achieved via the
use of a conventional AC dimmer pack.
• This xture may be mounted in any SAFE position provided there is enough room for
ventilation.
• It is important never to obstruct cooling vents pathway. Mount the xture using a
suitable “C” or “O” type clamp. The clamp should be rated to hold at least 10x the xture’s
weight to ensure structural stability. Do not mount to surfaces with unknown strength, and
ensure properly “rated” rigging is used when mounting xutres overhead.
• Adjust the angle of the xture by loosening both knobs and tilting the xture. After
nding the desired position, retighten both knobs.
• Safety cables MUST ALWAYS be used.
• Never mount in places where the xture will be exposed to rain, high humidity, extreme
temperature changes or restricted ventilation.
Troubleshooting
Symptom Solution
Fixture Auto-
Shut Off
If it light output has stopped, the unit may have shut itself off due to
high heat. This is to protect the xture from overheating. Clear the
cooling vents of obstructions, or return the unit for service.
Beam is Dim Check optical system and clean excess dust/grime. Also ensure that
the 220V/110V switch is in the correct position, if applicable.
No Power Check fuse, AC cord and circuit for malfunction.
Fixture Not
Responding /
Responding Er-
raticly
Make sure all connectors are seated properly and securely.
Check all cables for defects.
Reset xture(s).