3. SETUP
Fuse Replacement
CAUTION!TheHushPar™Theatrikutilizesahigh-outputswitch-modepowersupply
withaninternalfuse.Undernormaloperatingconditions,thefuseshouldnotrequire
replacement.Thefuseiseldreplaceable,howeveritisanadvancedproceduresuited
toqualiedindividuals.ShouldyourHushPar™Theatrikfuserequirereplacement,please
contact Blizzard Lighting for instructions, or to return your unit for service.
Mounting & Rigging
•Slidethebarndoorassemblyintothegroovesonthefrontofthexture.(optional)
•Securelyconnectthepowercabletoapowersocket.Dimmingcanbeachievedviathe
use of a conventional AC dimmer pack.
•ThisxturemaybemountedinanySAFEpositionprovidedthereisenoughroomfor
ventilation.
•Itisimportantnevertoobstructcoolingventspathway.Mountthextureusinga
suitable“C”or“O”typeclamp.Theclampshouldberatedtoholdatleast10xthexture’s
weighttoensurestructuralstability.Donotmounttosurfaceswithunknownstrength,and
ensureproperly“rated”riggingisusedwhenmountingxutresoverhead.
•Adjusttheangleofthexturebylooseningbothknobsandtiltingthexture.After
ndingthedesiredposition,retightenbothknobs.
•SafetycablesMUSTALWAYSbeused.
•Nevermountinplaceswherethexturewillbeexposedtorain,highhumidity,extreme
temperature changes or restricted ventilation.
Troubleshooting
Symptom Solution
FixtureAuto-
ShutOff
If it light output has stopped, the unit may have shut itself off due to
highheat.Thisistoprotectthexturefromoverheating.Clearthe
cooling vents of obstructions, or return the unit for service.
BeamisDim Checkopticalsystemandcleanexcessdust/grime.Alsoensurethat
the220V/110Vswitchisinthecorrectposition,ifapplicable.
NoPower Check fuse, AC cord and circuit for malfunction.
FixtureNot
Responding /
RespondingEr-
raticly
Make sure all connectors are seated properly and securely.
Check all cables for defects.