3. SETUP
Fuse Replacement
CAUTION! The HotStik™ utilizes a high-output switch-mode power supply
with an internal fuse. Under normal operating conditions, the fuse should
notrequirereplacement.Thefuseiseldreplaceable,howeveritisan
advancedproceduresuitedtoqualiedindividuals.ShouldyourHotStik™
fuserequirereplacement,pleasecontactBlizzardLightingforinstructions,
or to return your unit for service.
Connecting A Bunch of HotStik™ Fixtures
You will need a serial data link to run light shows using a DMX-512
controllerortorunshowsontwoormorexturessettosyncinmaster/
slaveoperatingmode.Thecombinednumberofchannelsrequiredbyall
thexturesonaserialdatalinkdeterminesthenumberofxturesthe
data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also,connectingmorethan32xturesononeserialdatalinkwithoutthe
use of a DMX optically-isolated splitter may result in deterioration of the
digital DMX signal. The maximum recommended cable-run distance is 500
meters(1640ft).Themaximumrecommendednumberofxturesona
serialdatalinkis32xtures.
Data/DMX Cabling
Tolinkxturestogetheryou’llneeddatacables.Youshouldusedata-
gradecablesthatcancarryahighqualitysignalandarelessproneto
electromagnetic interference.
Forinstance,Belden©9841meetsthespecicationsforEIARS-485
applications. Standard microphone cables will “probably” be OK, but note
that they cannot transmit DMX data as reliably over long distances. In
any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms