DMX Mode
Allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with
DMX, please read the DMX Primer on page #15.
1.) The ROCKLITE RGBW is capable of operating with either 4 or 8 DMX chan-
nels. To use the xture in 4-channel mode, use the <MENU> button to select
d001 on the LED Readout.
2.) To operate the xture in 8-channel mode, use the <MENU> button to select
A001 on the LED Readout.
Stand-Alone, Master/Slave, Sound Active Modes:
Allows a single or Master/Slaved units to run factory installed programs at user selectable
speeds.
1.) To set the xture in Flash/Fade mode, select
FF01-FF99 (Fade Mode,
slowest to fastest) or
CC01-CC99 To con rm, press the <SAVE> button.
2.) To use the xture in demo mode, select
dEoo, then press the <SAVE>
button to con rm.
3.) Each xture is a master by default. To set the xture as a slave, use the
<MENU> button to reach
SLAv, then press the <SAVE> button to con rm.
Sound Acitve Mode:
1.) To use sound active mode, select either
SouD.
2.) Press the <SAVE> button to con rm.
Manual Mode (Color Preset Mode):
Allows a single unit to display a variety of colors without a DMX controller.
1.) Reach the manual adjustment by using the <MENU> button to reach b001
.
Adjust each color by using the <SAVE>, <UP> and <DOWN> buttons to se-
lect
r001-r255, g001-g255, b001-b255 or u001-u255 (Red,
Green, Blue and White, respectively), and adjusting between 1 (lowest) and 255
(highest) for each color.
To con rm, press the <SAVE> button.
Page 9
ROCKLITE AW Manual Rev. A Copyright (c) 2011 Blizzard Lighting, LLC
Fixture Linking (Master/Slave Mode)
1. Connect the (male) 3 pin connector side of the
DMX cable to the output (female) 3 pin connector of
the rst xture.
2. Connect the end of the cable coming from the
rst xture which will have a (female) 3 pin connec-
tor to the input connector of the next xture con-
sisting of a (male) 3 pin connector. Then, proceed
to connect from the output as stated above to the
input of the following xture and so on.
A quick note: Often,
the setup for Master-
Slave and Standalone
operation requires that
the rst xture in the
chain be initialized for
this purpose via either
settings in the control
panel or DIP-switches.
Secondarily, the xtures
that follow may also re-
quire a slave setting.
Check the “Operating Adjustments” section in this manual for com-
plete instructions for this type of setup and con guration.
Mounting & Rigging
This xture may be mounted in any SAFE position provided there is
enough room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the
xture using a suitable “C” or “O” type clamp. The clamp should be
rated to hold at least 10x the xture’s weight to ensure structural sta-
bility. Do not mount to surfaces with unknown strength, and ensure
properly “rated” rigging is used when mounting xutres overhead.
Adjust the angle of the xture by loosening both knobs and tilting the
xture. After nding the desired position, retighten both knobs.
• When selecting installation location, take into consideration lamp
replacement access (if applicable) and routine maintenance.
• Safety cables MUST ALWAYS be used.
• Never mount in places where the xture will be exposed to rain,
high humidity, extreme temperature changes or restricted ventilation.