Manual

Operation Method ③- 
■Set for Warning and Boost limiter
1.Use ▼▲ to choose warning when the display brinks,
then press to decide.
  (SET shows and WR brinks)
2.Use ▼▲ to choose the boost pressure, then press to decide.
  Off~3.00hkPa(43.5PSI)
   
   WR ON … WR shows 
   WR OFF … WR not shows
3.Use ▼▲ to choose boost limiter, then press (-99~100)
    
 0 ……………… Limiter Off
 
 
 -99~-1  … When the set pressure of boost hits
          control of decreasing until the set pressure of DUTY.
 
 1~100  …… When the set pressure of boost hits  
          control of increasing until the set pressure of DUTY.
 
 ※LO/HI can be set on different setting.
<Example>Set Pressure of DUTY is 50.
   ・If the limiter is set -20,
    it will be controled 30 when the warning hits.
    
   ・If the limiter is set 20,
    it will be controled 70 when the warning hits.
     
12