Installation guide

HIGH POWER WALL CONNECTOR
2
SPECIFICATIONS
SPECIFICATIONS
The maximum rating for the High Power Wall Connector is 20 kW or 80 amps at 240 volts. Your vehicle will charge from 200 to 240 volts.
120V ABOVE GROUND (common in North America) 230V ABOVE GROUND (common in Europe, Asia, and Australia)
Voltage and Wiring
240V AC single-phase: L1, L2, and safety ground
208V AC 3-phase, wye-connected: Any 2 phases, and safety ground.
240V AC 3-phase, delta-connected: With center tap on one leg, use only the
two phases on either side of the center tap. The two phases must both measure
120V AC to ground. Do not use the third leg (208V “stinger”).
230V AC single-phase: LINE, NEUTRAL, and EARTH.
Current
Maximum 100A Circuit Breaker.
The maximum current for charging the vehicle is 80A or 20 kW.
At 240V, this will be 19 kW maximum.
Maximum 100A Circuit Breaker.
The maximum current for charging the vehicle is 80A or 20 kW.
At 230V, this will be 18 kW maximum.
Frequency 60 Hz 50-60 Hz
Cable Length Approximately 25’ (7.6 m)
Bracket Dimensions
Height: 15” (382 mm)
Width: 6.22” (158.2 mm)
Depth: 3.7” (96 mm)
Weight (including bracket) 20 lbs (9 kg)
Operating Temperature
-22°F to 113°F
-30°C to 45°C
Storage Temperature
-58°F to 185°F
-50°C to 85°C
Enclosure Rating
Type 3R IP 44
Agency Approvals
UL, FCC Part 15 EN, IEC