Instruction Manual
Charge on.
Page 2 7 o f 3 7 Blink IQ 2 0 0
Level 2 AC EVSE Instruction Manual 1 0 / 9 / 2 0 1 9
9 .2 . Sta tion Settings
Configuration Item
Description
Default Hours of O peration Settings
Default Hours of Operation
Settings
The default Hours of O peration. Settings sent from the Central System will supersede these
default settings.
W arning Settings
Temperature Low
The value in Celsius at which the charger will send a low temperature warning.
Temperature High
The value in Celsius at which the charger will send a high temperature warning.
Voltage Low
The value at which the charger will send a low voltage warning.
Voltage High
The value at which the charger will send a high voltage warning.
General Settings
Output Power Type
The output power type of the Blink Product.
Power Phase Connected
The power phase configuration of the Blink Product.
Max Amperage HW Setting
The maximum current output for the Blink Product.
Max Amperage FW Setting
The configurable (and de-ratable) maximum current for the Blink Product.
PW M Amperage
The amperage used by the PW M interface connected to the EV.
Real Amperage
The real-time measured amperage.
Cold Load Pickup Max Delay
The maximum delay (in seconds) before a charging session is resumed after power is
reapplied after a power outage. The value is configurable between 120 and 720 seconds.
EV Connect Timeout
The interval (in seconds) after a successful authorization that a user has to attach the charge
connector to their EV before the charge session is cancelled.
Plug and Charge ID
If the value is present, the Blink Product needs to support plug and charge scenario by using
the specific identifier. If the value is absent, authorization for each session is required.
Offline Authorize
Specifies whether users can initiate a charge session using the contactless reader
(i.e. RFID Card) while a unit is offline.
Authorize Timeout
The interval (in seconds) that the Blink Product will attempt to connect to the Central System
before an offline session is authorized O R cancelled (depending on the O ffline Authorize
setting).
Reservation Supported
This setting is reserved for future use.
Resume Charge After Reboot
Indicates if the Blink Product will resume the charge session after a power cycle. If the setting
is O n, the charge session will resume according to UL regulations. If the setting is Off, the
charge session will not resume after a power cycle.
Dim O ption
The interval (in minutes) of touch screen inactivity before the LCD reduces its brightness based
on the Dim Intensity setting. If touch screen activity is detected, the LCD will display using it
maximum brightness setting.
Dim Intensity
The percentage of the maximum LCD brightness which will apply if the Dim Option is enabled.
If 0% is selected, the display will be turned off after the Dim O ption time interval.
Odometer Screen
Indicates if the O dometer Screen will be displayed to users during the authorization process.
This setting primarily applies to fleet applications.
Time Zone
The local time zone of the Blink Product.
Default Price Settings
Default Pricing Settings
The default Price Settings. Settings sent from the Central System will supersede these default
settings.