Instruction Manual
Charge on.
Page 1 5 o f 3 7 Blink IQ 2 0 0
Level 2 AC EVSE Instruction Manual 1 0 / 9 / 2 0 1 9
6 .3 .1 0 . Remo ve the clear plastic co ver fro m the terminal blo ck.
6 .3 .1 1 .
Attach the crimped ring terminals to the terminal blo ck inside the Blink Pro duct.
Figure 6 Terminal Blo ck
6 .3 .1 2 .
Ensure that the terminal blo ck bo lts are tightened using the fo llo wing to rque specificatio ns:
Adva nced a nd Sma rt M odels
• L1 and L2 : 7 0 Inch-Po unds (8 Newto n-Meters)
• G ro und: 2 6 Inch-Po unds (3 N ewto n-Meters)
Kiosk M odel
• L1 and L2 : 7 Inch-Po unds (0 .8 N ewto n Meters)
• G ro und: 7 Inch-Po unds (0 .8 N ewto n Meters)
CAUTION W ARN IN G: RISK OF FIRE
Failure to use the pro per to rque specs co uld result in a fire and/ o r damag e to damag e to
the equipment. Proper to rque to o ls and metho ds must be used. Blink Product installers may
be held liable fo r the impro per installation o f a unit, which includes the use o f impro per
to rque to o ls and metho ds.
6 .3 .1 3 .
Re-attach the clear plastic co ver to the terminal blo ck.