Contact your lighting representative at info@epartslighting.com P: 754.702.2709 Charge on.
Charge on. © 2 0 1 9 by Blink N etw ork , LLC N o part o f the co ntents o f this do cument may be repro duced o r transmitted in any fo rm o r by any means witho ut the express written permissio n o f Blink N etw ork , LLC. The co ntents o f this do cument have been verified by the manufacturer to be co nsistent with the described co mpo nents; ho wever, inco nsistencies so metimes o ccur. Such inco nsistencies sho uld be bro ug ht to the attentio n o f an Blink N etw ork , LLC representative.
Charge on. 1. IM PO RTAN T SAFETY IN STRUCTIO N S ..................................................................................................... 4 2. IN TRO DUCTIO N ................................................................................................................................... 6 3. PRO DUCT O VERVIEW ........................................................................................................................... 6 4. PRO DUCT SPECIFICATIO N S ....................
Charge on. 1 . IM PO RTAN T SAFETY IN STRUCTIO N S Befo re installing o r using the Blink N etw ork , LLC (Blink) electric vehicle supply equipment (EVSE), read all these instructio ns, paying particular attentio n to any W ARN IN G and CAUTIO N marking s in this do cument and o n the Blink Pro duct. Yo u sho uld also review any instructio ns included with yo ur electric vehicle (EV) as they pertain to vehicle charg ing .
Charge on. FCC Rules a nd Industry Ca na da License-Ex empt RSS Sta nda rd(s) • This device co mplies with Part 1 5 o f the FCC Rules. Chang es o r mo dificatio ns are no t expressly appro ved • Eng lish: This device co mplies with Industry Canada licence-exempt RSS standard(s).
Charge on. 2 . IN TRO DUCTIO N This Instructio n Manual describes ho w to pro perly install the Blink IQ 2 0 0 Level 2 AC EVSE (Blink Pro duct). Co ntact the Blink Suppo rt Center at 1 -8 8 8 -9 9 8 -BLIN K (2 5 4 6 ) fo r tro ublesho o ting assistance and additio nal technical questio ns.
Charge on. 4 . PRO DUCT SPECIFICATIO N S BLIN K IQ 200 PRODUCTS POW ER SPECIFICATIONS ADVANCED CHARGING STATION Input/ O utput Power (Max.) Input/ O utput Power (Standby) <10W Standby 2.9, 3.8, 5.8, 7.7, 9.6, 15.4, 17.3, 19.2kW Software Selectable: 12A, 16A, 24A, 32A, 40A, 64A, 72A, 80A Circuit Breaker O ptions 19.2W Max. Input O nly 0.
Charge on. 5 . PRE-IN STALLATIO N IN STRUCTIO N S 5 .1 . Sa fety a nd Grounding 5 .1 .1 . Sa fety Check CAUTIO N : DISCO N N ECT ELECTRICAL PO W ER PRIO R TO IN STALLIN G THE BLIN K CHARG IN G STATIO N . FAILURE TO DO SO MAY CAUSE PHYSICAL IN JURY O R DAMAG E TO THE ELECTRICAL SYSTEM AN D BLIN K PRO DUCT. The Blink Pro duct sho uld be installed o nly by a licensed co ntracto r, and/ o r a licensed electrician in acco rdance with all applicable state, lo cal and natio nal electrical co des and standards.
Charge on. 5 .2 . Conduit & Brea k er Size Guide All Specifications are Per Charging Station or Port Max.
Charge on. 5 .3 . M ounting O ptions Fig ure 1 5 .4 . Mo unting O ptio ns Product Pla cem ent Tips 5 .4 .1 . Kiosk a nd Sm a rt Unit Pla cem ent • Kio sk units sho uld be installed within 1 5 0 ft. (line-o f-sig ht) o f the farthest Smart unit. • W alls, pillars, and barriers may affect the ability fo r a Smart unit to co mmunicate with a Kio sk unit. • Kio sk can pro vide access co ntro l fo r up to 2 0 seco ndary Smart Charg ing Statio ns. 5 .4 .2 .
Charge on. 6 . IN STALLATIO N IN STRUCTIO N S 6 .1 .
Charge on. 6 .3 . Insta lla tion Procedure 6 .3 .1 . O pen the Blink Pro duct bo x and lo cate the mo unting bracket. Fig ure 2 6 .3 .2 . Mo unting Bracket Drill ho les in the wall o r mo unting surface fo r the mo unting bo lts. N ote: A reco mmended mo unting heig ht is 4 0 inches (1 0 1 6 mm) fro m finish g rade to the bo tto m o f the mo unting bracket. N ote: Fo llo w applicable accessibility requirements fo r the mo unting po sitio n.
Charge on. 6 .3 .4 . Remo ve the to p co ver fro m the Blink Pro duct using a Security T2 0 driver to lo o sen the 7 screws. Fig ure 3 6 .3 .5 . co ver (A o r B) based o n the desired co nduit entry po int. Remo ve the appro priate Fig ure 4 6 .3 .6 .
Charge on. 6 .3 .7 . Attach the pro duct to the mo unting bracket using the 4 included mo unting bo lts and a Security T2 0 Driver using a to rque fo rce o f 1 3 Inch-Po unds (1 .5 N ewto n Meters). CAUTIO N Do no t o vertig hten the mo unting bo lts as damag e may o ccur. Fig ure 5 6 .3 .8 . Pro duct Installatio n Using the appro priate wire stripping to o l and crimping to o l specified in Ta ble 2 Required for Insta lla tion , crimp the included ring terminals to the wires.
Charge on. 6 .3 .1 0 . Remo ve the clear plastic co ver fro m the terminal blo ck. 6 .3 .1 1 . Attach the crimped ring terminals to the terminal blo ck inside the Blink Pro duct. Fig ure 6 Terminal Blo ck 6 .3 .1 2 . Ensure that the terminal blo ck bo lts are tig htened using the fo llo wing to rque specificatio ns: Adva nced a nd Sm a rt M odels • L1 and L2 : 7 0 Inch-Po unds (8 N ewto n-Meters) • G ro und: 2 6 Inch-Po unds (3 N ewto n-Meters) Kiosk M odel • L1 and L2 : 7 Inch-Po unds (0 .
Charge on. 6 .3 .1 4 . Fig ure 7 Po wer Switch 6 .3 .1 5 . Re-attach the to p co ver to the Blink Pro duct using a Security T2 0 Driver and a to rque fo rce o f 1 3 Inch-Po unds (1 .5 N ewto n Meters). CAUTIO N Do no t o vertig hten the mo unting bo lts as damag e may o ccur.
Charge on. 6 .3 .1 6 . Apply po wer to the Blink Pro duct. 6 .3 .1 7 . If applicable, co il the charg e cable aro und the Blink Pro duct and attach the charg ing co nnecto r to the ho lster.
Charge on. 7 . SETUP IN STRUCTIO N S 7 .1 . W eb Porta l Access 7 .1 .1 . Co ntact the Blink N etwo rk Suppo rt Center at 1 -8 8 8 -9 9 8 -BLIN K (2 5 4 6 ) to o btain the W i-Fi pa ssw ord AN D the W eb Porta l pa ssw ord . 7 .1 .2 . Using a co mputer, a tablet, o r a smartpho ne that suppo rts W i-Fi, bro wse fo r available netwo rks. 7 .1 .3 .
Charge on. 7 .2 . Cha nging the M a x im um O utput (Cha rging) Current of a Cha rging Sta tion IM PO RTAN T: The maximum o utput (charg ing ) current o f the Blink Pro duct must o nly be adjusted by autho rized perso nnel. The maximum o utput (charg ing ) current must no t be adjusted after the Blink Pro duct is co mmissio ned.
Charge on. 7 .3 . Connecting a Sm a rt Unit to a Kiosk (Sm a rt Units O nly ) 7 .3 .1 . O n the Configura tion pag e o f the Smart Unit, select the Com m unica tion Settings tab. Fig ure 1 3 7 .3 .2 . O n the Com munica tion Settings tab, enter the Serial N umber o f the Kio sk in the Ga tew a y Seria l N um ber field. The Serial N umber o f the Kio sk can be fo und o n the pro duct label o n the left side o f the unit. Fig ure 1 4 7 .3 .3 .
Charge on. 8 . O PERATIN G IN STRUCTIO N S 8 .1 . Sta rting a Cha rge Session 8 .1 .1 . Release the charg ing co nnecto r fro m the ho lster and co nnect it to the EV. 8 .1 .2 . To uch the Main Screen to beg in the autho rizatio n pro cess. Fig ure 1 5 8 .1 .3 . Main Screen Kiosk O nly: Enter the Unit # o f the charg ing statio n then to uch EN TER. The Unit # o f a charg ing statio n is lo cated o n a label o n the rig ht side o f the unit.
Charge on. 8 .1 .4 . Initiate a charg e sessio n using o ne o f the fo llo wing autho rizatio n metho ds: • • • • 8 .1 .5 . RFID Card Remo te Start Co mmand (Using a Mo bile App) Blink Co de (If Applicable) Smart Credit Card / Apple Pay / G o o g le Pay (May no t be included in the initial pro duct o ffering ) The Autho riz ing screen will appear while the unit co mmunicates with the Central System. Fig ure 1 7 8 .1 .6 . O nce the Charg e Co nfirmatio n screen appears, select the Cha rge butto n.
Charge on. 8 .1 .7 . W hile the EV is being charg ed, the Charg ing screen will be displayed. Fig ure 1 9 8 .1 .8 . W hile the EV is co nnected but no t being charg ed, the O ccupying screen will be displayed.
Charge on. 8 .2 . Stopping a Cha rge Session 8 .2 .1 . Disco nnect the charg ing co nnecto r fro m the EV at any time to sto p the charg e sessio n. 8 .2 .2 . O nce the sessio n has been sto pped, the Co st Summary screen will appear (if applicable). Fig ure 2 1 8 .2 .3 . To uch the CLO SE butto n o r wait until the screen times o ut. The Sessio n Ended screen will appear. Fig ure 2 2 8 .2 .4 . Pag e 2 4 o f 3 7 Co st Summary Screen Sessio n Ended Screen N ext, the Main Screen will appear.
Charge on. 8 .3 . Status Indicator Sta tus Indica tor Description Definition N ot Illuminated Power is O FF Flashing Yellow Device is N ot Ready (i.e. Booting, Upgrading Firmware, etc.) Steady Yellow Device is Unavailable (i.e.
Charge on. 9 . CO N FIGURATIO N 9 .1 . Fa ctory Settings 9 .1 .1 . Initially, the Fa ctory Settings tab will appear, which reflects the items which have been co nfig ured at the facto ry. Fig ure 2 3 9 .1 .2 . W eb Po rtal: Facto ry Setting s The fo llo wing table pro vides an o verview o f each item. Configuration Item Description Charge Point Vendor The name of the Blink Product Vendor. Charge Point Model The Model N umber of the Blink Product.
Charge on. 9 .2 . Sta tion Settings Configuration Item Description Default Hours of O peration Settings Default Hours of O peration Settings The default Hours of O peration. Settings sent from the Central System will supersede these default settings. W arning Settings Temperature Low The value in Celsius at which the charger will send a low temperature warning. Temperature High The value in Celsius at which the charger will send a high temperature warning.
Charge on. GPS Information Latitude The latitude of the Blink Product. Longitude The longitude of the Blink Product. 9 .3 . O CPP Settings Configuration Item Description Remote Service Settings Remote Service Type Specifies the protocol that the Blink Product will use to communicate with a Central System. Service Settings Charge Point ID The identity of the charger as known by the Central System. This setting is typically the Charge Point Serial N umber.
Charge on. OCPP1.6 Settings OCPP1.6 Settings 9 .4 . Settings based on the O CPP1.6 specification. Comm unica tion Settings Configuration Item Description N etwork Mode The network mode that the Blink Product will use to communicate with a Central System. UI Mode Direct The Blink Product will communicate directly with a Central System. Gateway The Blink Product will act as a Gateway for other units. Client The Blink Product will communicate through a Gateway unit.
Charge on. W i-Fi Settings Security Indicates the type of security which is used for the W i-Fi connection. EAP Mandatory for the following security methods: IEEE8021X User N ame Mandatory for the following security methods: W PA_EN TERPRISE, W PA2_EN TERPRISE, W PA2_EN TERPRISE_SHA256, IEEE8021X Password SSID Password to access a W i-Fi network. W i-Fi MAC Address The MAC address of the W i-Fi adapter. W i-Fi Signal Strength The signal strength (dBm) of the W i-Fi adapter.
Charge on. 9 .5 . M a intena nce Settings 9 .5 .1 . The M a intena nce setting s can be accessed by selecting the M a intena nce link o n the left pane. Fig ure 2 4 W eb Po rtal: Maintenance 9 .5 .2 . Soft Reboot Reboot butto n. 9 .5 .3 . Reset Fa ctory Defa ults Reset to M FG Defa ults butto n. 9 .5 .4 . Cha nge Sta tic Im a ge on M a in Screen • • Select the Choose File butto n. • Select the Uploa d butto n. N avig ate to an imag e which is 8 0 0 px X 4 1 0 px. 9 .5 .5 .
Charge on. 9 .6 . Loca l Loa d M a na gem ent Sta tus (LLM Sta tus) The lo cal lo ad manag ement status o f a unit can be accessed by selecting the LLM Sta tus link o n the left pane. Fig ure 2 5 9 .7 . W eb Po rtal: LLM Status Security Settings The security setting s o f a unit can be accessed by selecting the Security link o n the left pane. Fig ure 2 6 9 .8 .
Charge on. 1 0 . TRO UBLESHO O TIN G 1 0 .1 . Troubleshooting Ta ble Situation Screen Displayed Action Out of Service: Station Disabled Out of Service: Internal Maintenance 1. The unit has been disabled and is out of service. 2. Call 1-888-998-BLIN K (2546) for assistance. 1. The unit is performing internal maintenance (i.e. software update). 2. W ait until the unit has completed its internal maintenance and is available. 1. The unit is outside the configured hours of operation. 2.
Charge on. Payment Card Declined Blink Code is not Valid Blink Code Access is Unavailable Kiosk O nly: The Selected Blink Unit is Invalid Kiosk O nly: The Selected Blink Unit is Currently Unavailable Pag e 3 4 o f 3 7 Blink IQ 2 0 0 1. There is an issue with the card or account (See Table 7 Reference Codes). 2. Call 1-888-998-BLIN K (2546) for assistance. 1. There is an issue with the card or account. (See Table 7 Reference Codes). 2. Call 1-888-998-BLIN K (2546) for assistance. 1.
Charge on. Fault with Automatic Reset Fault with Manual Reset Fault with N o Reset 1. A fault occurred (See Table 6 Error Codes). 2. Record the Error Code. 3. W ait 15 minutes for the system to recover from the fault or touch the RESET button to manually reset the system. 4. Call 1-888-998-BLIN K (2546) for assistance. 1. A fault occurred (See Table 6 2. Record the Error Code. 3. Touch the RESET button to manually reset the system. 4. Call 1-888-998-BLIN K (2546) for assistance. 1.
Charge on. 1 0 .4 . Error Codes Error Code Error N ame Error Description 1000 N oError N o error to report. 1001 GroundFailure Ground fault circuit interrupter has been activated. Same as CCID protection. 1002 MissingGroundFailure Failure of missing ground of AC inputs. 1003 PowerSwitchFailure Failure to control power switch. 1004 PowerMeterFailure Failure to read power meter. 1005 ReaderFailure Failure with ID tag reader. 1006 DisplayFailure Failure with LCD display or touch panel.
Charge on. 11. GEN ERAL CARE The exterio r o f the Charg er is desig ned to be waterpro o f and dust pro o f. To ensure pro per maintenance o f the charg er, fo llo w these g uidelines: • Despite the water resistance o f the enclo sure, DO N O T direct streams o f water at the unit. Clean the unit with a so ft, damp clo th. • • • Make sure the charg ing co nnecto r is returned to the ho lster after a charg e sessio n to avo id damag e.