Installation Guide
Conguration
5. Conguration
Before making input, output and GPIO connections, an
initial PowerZone Connect DSP amplier conguration
should be established. It is particularly important that
the output amplier format is congured appropriately
for the speakers that are to be connected.
Conguration requires that PowerZone Connect DSP
ampliers are connected to mains power and network
services. These connections are described in the
following two sections.
5.1 Mains Power Connection
PowerZone Connect ampliers incorporate a power factor
corrected power supply and can be used with mains input
voltage from 100V AC to 240V AC, 50/60Hz. Use the mains
cable supplied with the amplier and connect it to a switched
mains supply.
PowerZone Connect ampliers have no mains power switch
and are operational as soon as mains power is connected.
5.2 Network Services
PowerZone Connect ampliers are congured via a
web page interface called PowerZone Control. Before
the conguration menus can be accessed, PowerZone
Connect ampliers must be connected to the same TCP/
IP network as the computer or mobile device that is to
be used for conguration access.
Wired (Ethernet) Network Connection
To connect a PowerZone Connect amplier to a TCP/IP
network using a wired connection (Ethernet) follow the steps
below.
1. Use an Ethernet cable to connect the PowerZone Connect
amplier rear panel Network Control socket to a free socket on
a network router or network switch.
2. With the PowerZone Connect amplier connected to mains
power, wait for the front panel Network indicator to illuminate
green to indicate that the amplier has been assigned an IP
address.
3. Use a network scanner app to identify the IP address
assigned by the network router to the PowerZone Connect
amplier.
4. Open a computer or mobile device web browser and enter
the IP address identied in the Step 3 above. The amplier
conguration web page interface will now open.
Note: If a PowerZone Connect amplier is power cycled it is possible
that the TCP/IP network router will assign it a different IP address,
leaving its conguration page inaccessible via the previous address.
If this occurs, a network scanning app can be used to identify the
new IP address. Alternatively, the amplier can be congured to use
a xed IP address via the LAN conguration menu.
Wireless (WiFi) Network Connection
To connect a PowerZone Connect amplier to a TCP/IP
network using a wireless connection (WiFi) follow the steps
below.
1. With the PowerZone Connect amplier connected to mains
power, wait for the front panel WiFi indicator to illuminate
green.
2. Use a mobile, laptop or desktop device to search for available
WiFi networks. Connect to, PowerZone Connect (product
serial number)’ using the password, ‘password’. The amplier
serial number can be found on its rear panel.
3. Open a computer or mobile device web browser and enter
the IP address: 192.168.4.1. The amplier conguration web
page interface will open.
4. Select the Settings tab followed by WiFi > WiFi Mode >
Client to congure the amplier to connect to the required
WiFI network. The WiFi network name and password will be
required.
It is strongly recommended that the PowerZone Connect
amplier Access Point WiFi password is changed following
initial wireless connection.