Installation Guide
Installation
4. Installation
Note: The rack mounting and desk/wall mounting components
described and illustrated in Sections 4.1 to 4.3 are not supplied
with PowerZone Connect ampliers but are available to purchase as
accessories. Contact your amplier re-seller for more information.
4.1 PowerZone Connect Mounting
The PowerZone Connect ampliers are shipped without rack
mount hardware attached but can be congured for rack
installation using one standard rack ‘ear’ and one half-rack
extension piece as illustrated in Diagram 3a. The installation
and equipment rack should be congured to provide
appropriate ventilation airow space around the sides and
rear of the amplier as illustrated in as illustrated in Diagram
1a. Ventilation airow space of at least 25 mm (1 in) should
be maintained along at least one side of the amplier at all
times. Ventilation apertures are also located on the rear panel
of the amplier and must not be obstructed. It is important to
retain at least 80 mm (3.1 in) free space for airow behind the
amplier rear panel.
In addition to rack mount ears, optional rack mount rear
support hardware is available and can be attached to the
amplier. Rear support hardware may be appropriate if
the amplier is to be used in a mobile rack or potentially be
subject to signicant movement. Diagram 3b illustrates the
use of rack mount rear support hardware.
Multiple PowerZone Connect ampliers can also be
mechanically connected using accessory connecting plates.
Diagram 3c illustrates the use of connecting plates.
Diagram 3a
PowerZone Connect
Rack Ear + Half-rack Extension.
Diagram 3b
PowerZone Connect
Rack Support hardware. 2 positions.
Rack Ear +
2 x M4 x 8
countersunk
Half-rack Extension +
2 x M4 x 8 countersunk
Rear Support + Button +
1 x M4 x 8
Connection Plate +
4 x M3 x 6 countersunk
Diagram 3c
2 x PowerZone Connect with Connection
Plate. 2 positions