5.4 PowerZone 1004 Mounting
Note: The rear support components described and
illustrated in Sections 5.4 are not supplied with
PowerZone ampliers but are available to purchase as
accessories. Contact your amplier re-seller for more
information.
The PowerZone 1004 amplier is shipped with
rack mount ‘ears’ attached as illustrated in Diagram
5a and is primarily intended to be installed in an
equipment rack. The installation and equipment
rack should be congured to provide appropriate
ventilation airow space around the sides and
rear of the amplier as illustrated in Diagram 1c.
Ventilation airow space of at least 25 mm (1 in) should be
maintained along at least one side of the amplier at all times.
Ventilation apertures are also located on
the rear panel of the amplier and must
not be obstructed. It is important to retain
at least 80 mm (3.1 in) free space for
airow behind the amplier rear panel.
In addition to rack mount ears, optional
rack mount rear support hardware is
available and can be attached to the
amplier. Rear support hardware may
be appropriate if the amplier is to be
used in a mobile rack or potentially be
subject to signicant movement. Diagram
5b illustrates the use of rack mount rear
support hardware.
Rack Ear +
2 x M4 x 8 csk
Diagram 5a
PowerZone 1004 rack ears. 2 positions.
Rear Support + Button +
1 x M4 x 8
Diagram 5b
PowerZone 1004 rear support hardware.
2 positions.