5.4 PowerZone 1004 Mounting
Note: The rear support components described and
illustrated in Sections 5.4 are not supplied with
PowerZone ampliers but are available to purchase as
accessories. Contact your amplier re-seller for more
information.
The PowerZone 1004 amplier is shipped with
rack mount ‘ears’ attached as illustrated in Diagram
5a and is primarily intended to be installed in an
equipment rack. The installation and equipment
rack should be congured to provide appropriate
ventilation airow space around the sides and
rear of the amplier as illustrated in Diagram 1c.
Ventilation airow space of at least 25 mm (1 in) should be
maintained along at least one side of the amplier at all times.
Ventilation apertures are also located on
the rear panel of the amplier and must
not be obstructed. It is important to retain
at least 80 mm (3.1 in) free space for
airow behind the amplier rear panel.
In addition to rack mount ears, optional
rack mount rear support hardware is
available and can be attached to the
amplier. Rear support hardware may
be appropriate if the amplier is to be
used in a mobile rack or potentially be
subject to signicant movement. Diagram
5b illustrates the use of rack mount rear
support hardware.
Rack Ear +
2 x M4 x 8 csk
Diagram 5a
PowerZone 1004 rack ears. 2 positions.
Rear Support + Button +
1 x M4 x 8
Diagram 5b
PowerZone 1004 rear support hardware.
2 positions.