User Guide
Table Of Contents
- USE & CARE GUIDE
- ATTENTION:
- I. Safety and Installation Warnings 4-7
- II. Location of Appliance 8-9
- i. Electrical Safety and Installation Warnings 10-11
- III. Gas Safety and Installation Warnings 11-12
- IV. Gas Leaks 13
- i. Checking for Gas Leaks 13-15
- ii. Unpacking Unit 15-16
- V. Gas Connections 16
- i. Natural Gas Requirements 16
- ii. Liquid Propane Gas and Tank Requirements 16-18
- iii. Transporting and Storing LP Gas 17-18
- VI. Installing the Appliance in an Island 19-22
- i. Outdoor Kitchen Ventilation 20-21
- ii. Building Specifications + Instruction 21-23
- iii. Installation Diagrams 23-24
- VII. First Time Operation 25
- i. Lighting the Appliance 25-26
- ii. Manually Lighting the Appliance 26-27
- iii. Flame Adjustment 27
- VIII. Cleaning your Appliance 28-29
- IX. Fuel Conversion 30-32
- Do not attempt to heat unopened containers on the griddle as pressure may build up and cause the container to explode.
- Never use charcoal or any other solid fuel in the griddle.
- Never cook without the drip pan in place.
- Never operate this griddle while under the influence of alcohol or drugs.
- Never place your fingers inside the observation openings in the griddle plate during removal or replacement of the griddle plate as they could be pinched. Never place your fingers inside the observation openings in the griddle at any time as injury co...
- Location of Appliance
- Gas Safety and Installation Warnings
- IMPORTANT: Never connect the appliance to an unregulated gas supply.
- Installation must conform with local codes or in the absence of local codes, to the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and Natural Gas Installation Code, CSA B149.1. All Natural Gas installations must conform to local codes or in the absence ...
- Leak Testing
- NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
- Never place your fingers inside the observation openings in the griddle plate during removal or replacement of the griddle plate as they could be pinched. Never place your fingers inside the observation openings in the griddle at any time as injury co...
- Never place your fingers inside the observation openings in the griddle plate during removal or replacement of the griddle plate as they could be pinched. Never place your fingers inside the observation openings in the griddle at any time as injury co...
- Natural Gas Requirements
- Liquid Propane (LP) Gas and Tank Requirements
- Installing the Appliance in a BBQ Island
- FIRST-TIME OPERATION
- Cleaning Your Appliance
- Fuel Conversion
- Warranty Registration
- Improper Maintenance, high cooking temperatures, excessive humidity, chlorine, fertilizers, lawn pesticides, chemicals, and salt can affect the Stainless Steel components and for these reasons, the warranties DO NOT COVER DISCOLORATION, SURFACE RUST, ...
- Locating the Product Serial Number:
- Blaze Product Registration
- Blaze Outdoor Products, Warranty Registration, 6620 Greenwell Springs Rd.
- Baton Rouge, LA 70805
Blaze Outdoor Products Instructional Book
Page | 14
Stop a leak by tightening the loose joint and/or resealing with thread sealant or Teflon tape, removing
sealant or
tape in the event of a flared connection or by replacing the faulty part with a replacement part
recommended by the manufacturer. Do not attempt to repair the cylinder valve if it is damaged. The
cylinder must be discarded to a proper LP tank location and then replaced.
If you are unable to stop a leak turn all control knobs back to the full OFF position, shut off the gas
supply to the appliance and release pressure in the hose and manifold by pushing in and turning any
of
the control valves one quarter turn counter-clockwise.
On LP systems, remove the cylinder from the appliance.
Call an authorized gas appliance service technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.
The below diagram is intended to show what a leaking connection would look like. These two locations
are not the only points to check nor the only potential areas for a gas leak to be present.
Leak Testing
All gas piping and connections must be tested for leaks after installation or service along with before each
use.
This includes all valves, pipe connections, joints, lines and every point from the gas
source to the burners.
All leaks must be corrected
immediately. Remember-before exchanging an empty bottle for a new one; make
sure all control valves are in
the “off” position. This can create a low flow of gas through the griddle. This would
require the tank to be disconnected from the regulator, and then reconnected to reset the regulator.
Open the valve (shut-off or ‘ON’ LP tank). Test for leaks by applying liquid soap solution to all joints. Bubbles forming
indicate gas leak.
The following diagram is for informational purposes only. These locations are not the only points to
check nor the only potential areas for a gas leak to be present. Ensure the leak test includes all
valves, pipe connections, joints, lines and every point from the gas source to the burners.