Manual
20
Condenser cleaning
A dirty or clogged condenser prevents proper airflow, reduces ice making capacity,
and causes higher than recommended operating temperatures that may lead to
component failure. Have the condenser cleaned at least once every six months.
1. Unplug the ice maker or disconnect power.
2. Gently pull off the lower front louver.
3. Remove dirt and lint from the condenser and the
unit compartment with the brush attachment of a
vacuum cleaner
.
4. Reassemble the lower front louver.
5. Plug in the ice maker or reconnect power.
Water distribution tube cleaning
When you find the ice cubes are incompletely formed or the output is low, the
water distribution tube may be blocked. Turn off the power button, gently take out
the water distribution tube, locate the holes in the distribution tube and use a
pointed object such as a toothpick to dredge the holes. Then put the water
distribution tube back to its original position. If the tube is badly blocked, clean it as
follows:
1. Shut off the water supply.
2. Disconnect the water hose from the distribution tube.
Condenser
Surface
DO NOT use solvent-based cleaning agents or abrasives on
the interior. These cleaners may transmit taste to the ice
cubes and damage or discolor the interior.