Operating instructions

28 Date Printed: 4/7/11
File: G:/pubdata/Manuals\english manuals\OM-KE/PE.pub OM KE/PE 1006 Version 1.10 Revised: December 2010
Installation Instructions
MOBILE HOME AND RESIDENTIAL ALCOVE, ROOF EXIT, PREFABRICATED CHIMNEY
Refer to Fig. 21, 22, and 23 Clearances from Table #I
BEFORE INSTALLATION
Side Shields and either Rear Shield OR Fan kit are required for these installations. They are easiest to mount before the
stove is installed. See instructions packed with each kit.
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed precisely. You
must also purchase (from the same manufacturer) and install the ceiling support package or wall pass through and "T"
section package, fire stops (when needed), insulation shield, roof flashing, chimney cap, etc. Maintain the proper
clearance to the structure as recommended by the manufacturer.
NOTES:
1. For MOBILE HOME AND RESIDENTIAL ALCOVE installations, use these instructions with Side Shield Kit (KE1107, S/SK1107;
PE1006, S/SP1003) and either Rear Shield (KE1107, R/SK1107; PE1006, R/SP1006) or Fan Kit: Z1714. Chimney connector
must be double wall close clearance type, and must be of same brand and model as listed prefabricated chimney. Single wall
pipe is not allowed in Mobile Homes or in Alcove Installations. Insulated chimney components must be a listed factory built
chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or UL-103HT in the USA. For MOBILE HOME
installation you also require the Outside Air Kit: FAKIT.
WARNING - DO NOT INSTALL IN SLEEPING ROOM
CAUTION - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND
CEILING/ROOF MUST BE MAINTAINED.
1. Set floor protection and stove in location; refer to the clearance dimensions listed on the label and in these instructions.
2. Mark the position for the hole in the ceiling and roof using a string and plumb bob.
3. Check that the intended location will not interfere with floor joists, ceiling joists, or rafters before proceeding further.
4. Mark the positions for the tie down and the hole for the outside air pipe.
5. Move the stove and using a saber saw with a suitable blade, cut a hole for the outside air pipe and install as per instructions. Drill
a pilot hole for the tie down.
6. Cut a pilot hole in the ceiling.
7. Cut a hole for the ceiling penetration components and frame in the sides of this hole in both the ceiling and roof. Refer to pipe
manufacturers installation instructions. Install the support box. Be sure all pipe parts, including outside air cap, flange, - collar and
pipe (and all stove options) are installed at this point before putting the stove in its final position.
8. Slide the stove back into position.
9. Install the tie down.
10. To install close clearance connector to the stove, slip the
lower (crimped) end inside the smoke collar. Fasten chimney
connector' to stove with screws provided. Slide connector up
and snap into ceiling support. (Make sure it "snaps" in
place.) Refer to the pipe manufacture’s Installation
Instructions.
11. Following the pipe manufacturer's Installation Instructions,
install chimney system into support box, slip the roof flashing
down over the chimney and secure to the roof, being careful
to keep the pipe centered in the opening.
NOTE: To meet the code, the chimney must extend above
the roof at least three feet and two feet above any area of the
roof within ten feet of the chimney termination.
12. Install the Outside Air Pipe 3” flex tube.
13. If the OPTIONAL Fan Kit is installed, the fan motors are
equipped with a three-prong (grounded) plug to prevent
shock hazard. THIS PLUG SHOULD BE INSERTED
DIRECTLY INTO A PROPERLY GROUNDED, THREE-
PRONGED RECEPTACLE. DO NOT CUT OR REMOVE
THE GROUNDING PRONG FROM THIS PLUG. Do not
route the power cord in front of or under this heater.
NOTE: In mobile home installations, the stove must be
securely fastened to the floor using the tie-downs provided.
ALSO, a #8 ground wire most be attached to the stove and an appropriate ground.
Fig. 30 Mobile Home, Residential Close Clearance and Alcove , Roof Exit