Installation Instructions
NOTE
Following are requirements for both KEJ and PEJ, to attain clearances on the previous page. Various shield and fan kits
are further described in the OPTIONS section, starting on page 29,
Where these instructions refer to “Listed, prefabricated chimney” that chimney and the accompanying close clearance
connector must be a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or UL-103HT
in the USA.
1. KE1107 / KEJ1107 use 8” flue size (this should not be reduced). PE1006 / PEJ1006 use 6” flue size.
2. Residential roof exit parallel or corner installation, may employ any listed, prefabricated chimney system and 24
gauge blue/black single wall chimney connector. *Blaze King does recommend the use of double wall pipe. Neither
side shields nor rear heat shield/fan kit are required. Installation instructions begin on page 17.
3. Residential roof exit with reduced side clearances is possible by adding side shields. Single wall chimney connector,
24 gauge, is permitted with any listed Prefabricated chimney system. Installation instructions begin on page 18.
4. Residential roof exit with reduced corner clearances is possible with both side shields-and either rear shield OR fan
kit installed. Single wall chimney connector, 24 gauge, is permitted with any listed prefabricated chimney system.
Installation instructions begin on page 17.
5. Residential close clearance installations require side shields, a rear shield OR fan kit, and one of the listed,
prefabricated HT chimney systems with matching double wall close clearance connector shown in figure 30. These
requirements are the same as for a Mobile Home installation, except for the outside air kit. Installation instructions
begin on page 17.
6. Residential wall exit, parallel and corner, use 24 gauge blue/black single wall chimney connector through a listed
wall thimble assembly, or a site-built brick thimble, into any listed, prefabricated chimney system, or a site-built
masonry chimney with tile liner. Neither side shields nor rear heat shield/fan kit are required. The horizontal section
of the chimney must be at least 18" below the ceiling. Installation instructions begin on page 18. *Blaze King
recommends the use of double wall pipe and two 45° elbows instead of a single 90° elbow. A minimum 36” rise is
recommended prior to any elbows being used.
7. Residential wall exit with reduced side clearances is possible by adding side shields. Single wall chimney connector,
24 gauge, is permitted. Connector must pass through a listed wall thimble assembly, or a site-built brick thimble, into
any listed, prefabricated chimney system, or a site-built masonry chimney with-tile liner. The horizontal section of the
chimney must be at least 18" below the ceiling. Installation instructions begin on page 18.
8. Residential wall exit with reduced corner clearances is possible with both side shields and either rear shield OR fan
kit installed. Single wall chimney connector, 24 gauge, is permitted. Connector must pass through a listed wall
thimble assembly, or a site-built brick thimble, into any listed, prefabricated chimney system, or a site-built masonry
chimney, with tile Liner. The horizontal section of the chimney must be at least 18” below the ceiling. Installation
instructions begin on page 21 (prefabricated chimney) or page 18 (masonry chimney).
9. Residential alcove, roof exit, requires a minimum ceiling height of 76". Also required are side shields, rear shield OR
fan kit, and one of the listed, prefabricated chimney systems with matching double wall close clearance connector
shown on page 28. For both KEJ and PEJ, minimum alcove width-is 47". Maximum alcove depth is 48". Minimum
distance from bottom of either stove model, to ceiling of alcove, is 76". Installation instructions begin on page 24.
10. Mobile Home installations are only allowed with a roof exit. Mobile homes require side shields, either rear shield OR
fan kit, an outside air kit, and one of the listed, prefabricated chimney systems with matching double wall close
clearance connector shown on page 28. In Mobile Homes, overall installed height of stove with chimney system
must be no less than 10.5 feet nor more than 20 feet. Installation instructions begin on page 24.
11. Clearance A is measured from the side of the stovetop. Clearance B is measured from the back center of the stove.
Clearances C, D and F are measured from the round chimney connector collar on the stovetop, not from the
chimney connector. Clearance E is measured from the back corner of the stovetop,