Operating instructions
23 Date Printed: 4/7/11
File: G:/pubdata/Manuals\english manuals\OM-KE/PE.pub OM KE/PE 1006 Version 1.10 Revised: December 2010
Clearances To Combustible Surfaces
Alcove Dimensional Requirements:
Minimum Width 47"(KE 51”), Maximum Depth 48", Minimum Height above Stove Top, 49"
Total Alcove height for Classic (PE/KE)= 76”/ 81.25”, Parlor (PE/KE)= 81”/ 84.50” and Ultra (PE/KE)= 82”/ 85.50”
“
FAILURE TO ALLOW THE REQUIRED CLEARANCES TO COMBUSTIBLE MATERIALS OR TO PROVIDE
ADEQUATE FLOOR PROTECTION CAN CAUSE A HOUSE FIRE. SUCH A FIRE CAN RESULT IN DAMAGES
TO PROPERTY AND SERIOUS INJURY OR DEATH.
PE1006 / PEJ1006
Residential Installations A B C D E F A B C D E F
Roof exit, parallel and corner 16”
410mm
9”
230mm
26.5”
675mm
16”
410mm
14”
360mm
24.75”
629mm
16”
410mm
9”
230mm
27”
690mm
16.5”
420mm
14”
360mm
25”
640mm
Roof exit, reduced side Use side shields 10”
254mm
9”
230mm
20.5”
520mm
16”
410mm
10”
254mm
9”
230mm
21”
534mm
16.5”
420mm
Roof exit, reduced corner Use side shields and
either fan kit or rear shield
6”
153mm
16.75”
425mm
6”
153mm
17”
433mm
Roof exit, close clearance Use side shields,
and either fan kit or rear shield
10”
254mm
6”
153mm
20.5”
520mm
13”
330mm
10”
254mm
6”
153mm
21”
534mm
13.5”
343mm
Wall exit, parallel and corner 16”
410mm
11”
230mm
26.5”
675mm
18”
460mm
14”
360mm
24.75”
629mm
16”
410mm
11
230mm
27”
690mm
18.5”
470mm
14”
360mm
25”
640mm
Wall exit, reduced side. Use side shields 10”
254mm
11”
230mm
20.5
520mm
18”
460mm
10”
254mm
11"
230mm
21”
534mm
18.5”
470mm
Wall exit, reduced corner. Use side shields
and either fan kit or rear shield
7”
180mm
17.75”
451mm
7”
180mm
18”
460mm
Alcove, roof exit. Use side shields, and either
fan kit or rear shield
10”
254mm
6”
153mm
20.5”
520mm
13’
330mm
9”
230mm
6”
153mm
20”
510mm
13.5”
343mm
Mobile Home Installation
Roof exit, parallel and corner Use side shields,
either fan kit or rear shield and outside air kit
10”
254mm
6”
153mm
20.5”
520mm
13”
330mm
6”
153mm
16.75”
425mm
10”
254mm
6”
153mm
21”
534mm
13.5”
343mm
6”
153mm
17”
433mm
KE1107 / KEJ1107
Fig.
21, 23
21, 23
21, 23
21, 23
24, 25, 26
24, 25, 26
24, 25, 26
22
21, 23
H= 18” (460 mm) in Canada, 16” in USA
Clearances To Combustibles In Inches (”) And millimeters (mm)
Fig. 21 Roof Exit Corner
Fig. 24 Wall Exit Side View
E
E
F
Fig. 26 Wall Exit Corner
H
Fig. 25 Wall Exit Parallel
H
H
H
Fig. 22 Roof Exit Alcove
H
Fig. 23 Roof Exit Parallel
H