Owner`s manual
THE CALDERA
Page 20
INSTALLATION INSTRUCTIONS Cont...
Vertical Installations
Always maintain the 1” clearance around the vent pipe (vertical), when passing through
ceilings, walls, roofs, enclosures, attic rafters or any combustible surfaces.
DO NOT PACK AIR SPACES WITH INSULATION.
Refer to the vent chart for maximum allowable vertical and horizontal installations.
When planning your installation determine if ceiling joists, roof rafters or other framing will
obstruct the vent system. You may have to use 45° elbows to navigate around any obstacles.
When passing through a flat ceiling install a Box/Wall thimble. Cut a 10” square hole and frame
as shown in the diagram opposite.
Ensure all pipe sections are fully twist locked.
NOTE: ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING.
NECESSARY CLEARANCES AND REQUIRMENTS MAY VARY FROM STATE TO STATE
(PROVINCE TO PROVINCE).