PRECAUTIONS
This appliance must be installed by a qualified gas installer and the installation
conform to applicable installation codes.
This appliance needs fresh air for safe operation and must be installed so there are
provisions for adequate ventilation air. Provide adequate clearance around air openings of
the appliance. Never obstruct front openings.
Provide adequate clearances for proper operation and servicing of the appliance.
This appliance must be properly connected to a venting system.
This appliance must NOT be connected to a chimney flue serving a solid-fuel appliance.
LOCATING GAS FIREPLACE
The venting system of this appliance must be installed in a location that is free of plumbing,
electrical wiring and heating or air conditioning ducts. Select a location that is accessible for
venting. See the ALLOWABLE TERMINATION LOCATIONS - page 45, in this manual.
ANCHORING UNIT
After determining the location, the appliance needs to be anchored to framing and floor.
Attach to the floor with two screws through the holes in the bottom of the appliance (see Figure
3D) The holes are located behind the bottom louver, one on the left, one on the right.
Attach to the frame by the
standoffs on top of the
unit (See Figure 3D)
The standoffs can be
adjusted by loosening the
screws on top of the
appliance
Figure 3D