User`s manual
57
IDLE RUN
Checks and adjustment of idle run shall be performed after ev-
ery engine maintenance procedure and in accordance with the
Maintenance Plan (page 49).
Once the idle run has been adjusted properly, the engine shall be
warmed up to its service temperature (for approx. 10 minutes)
Check the engine idle run.
Idle run: 1.600 ± 100 min
-1
(r.p.m.)
NOTE:
If you do not succeed in adjusting the idle run revolutions or if
these are irregular, contact an authorised Blata service centre.
In case the engine requires
further adjustment, set the
idle run using the throttle stop
screw.
Open the choke valve 2 - 3
times and re-check the idle run
revolutions.