User`s manual

50
FUEL SYSTEM
Remove the seat.
Unscrew the 3 bolts from the
front left and right tank covers
and remove these covers.
Unscrew the 3 xing bolts on
the fuel tank and lift the tank up
slightly.
Check all the fuel, vacuum and
pneumatic tubes for possible
deterioration, damage or leaks.
(A) Automatic vacuum valve
(B) Vacuum tube
(C) Fuel tube
If you nd any of the parts out of order or showing signs of leaka-
ge, have it replaced at an authorised Blata service.
Re-t the fuel tank to its initial position and tighten it using the
3 bolts provided. Beware to conduct the installation without any
damage or strangulation of pipes.
Fit the left and right fuel tank covers. When tightening the bolts,
always obey the prescribed torque.
Tightening torque: 1.5 Nm (1.11lbf.ft)
A
B
C