Specifications

Operating manual BDC3140 DBP/LPP
info@blastrac.eu
7/12
GB
Dimensions
Figure 3
Model
BDC3140 DBP
230/60 400/50 440/60
A (mm) 1600
B (mm) 1200
C (mm) 600
Weight (kg) 211 196 234
Model
BDC3140 LPP
230/60 400/50 440/60
A (mm) 1600
B (mm) 1200
C (mm) 600
Weight (kg) 215 200 238
[ NOTE ]
Storage conditions:
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
Operating conditions:
Maximum altitude: 800 m
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
Controls, indicators and connections
Figure 4
1. Dust container release lever
2. Castor lever
3. Main switch
4. Start button
5. Stop button
6. Voltage presence white indicator
7. Thermal protection operation red indicator
8. Compressor start/stop button (440V/60Hz - 230V/60Hz)
9. Compressor pressure governor (440V/60Hz -
230V/60Hz)
10. Compressor start/stop button (400V/50Hz)
11. Compressor pressure governor (400V/50Hz)
Inspections prior to starting
Figure 5
1. Inlet
Prior to starting, check that:
The lter is installed.
All latches are tightly locked;
The vacuum hose and tools have been correctly tted
into the inlet (1);
The bag or safety container is installed, if applicable.
Do not use the device if the lter is faulty.
Starting up
Figure 6
1. Castor brakes
Lock the castor brakes before starting the vacuum cleaner (1).
Starting/stopping the vacuum cleaner
Turn the switch (3) (gure 4) to “I” position to
electrically power the vacuum cleaner. The voltage
presence indicator (6) (gure 4) comes on.
Push the start button (4) (gure 4) to start the vacuum
cleaner.
Push the stop button (5) (gure 4) to stop the vacuum
cleaner.
Turn the switch (3) (gure 4) to “0” position to turn off
the electrical power of the vacuum cleaner.
WARNING!
The start/stop button (8 and 10) (gure 4) of the
compressor should always be in “I” position during
the operation.
WARNING!
Check the pressure of the air used to clean the
lters which is produced by the compressor.
It must never be superior than 5 bars, if necessary,
adjust it to the correct level using the related
pressure governors (9 e 11) (gure 4).
WARNING!
The activation of the indicator (7) (gure 4) signals
the operation of the vacuum unit thermal protection
due to the excessive electrical power draw of the
unit.