Specifications
Operating manual BDC3140 DBP/LPP 12/12
info@blastrac.eu
GB
Troubleshooting
Problem Cause Remedy
The vacuum cleaner does not start Lack of power supply Check for power at the socket.
Check the condition of the socket and
the cable.
If necessary, ask for assistance to
be performed by a manufacturer’s
technician.
The vacuum cleaner does not vacuum
correctly
Clogged lters Check the lter cleaning operation or
replace the lters.
Check the compressor functionality
(see the relative manual).
Make sure that the compressed air
nozzles are aligned with the cartridges.
Clogged vacuum hose Check the vacuum hose and clean it.
The vacuum cleaner suddenly stops Circuit breaker activation Check the circuit breaker adjustment.
Check the motor electrical input.
Empty the container.
If necessary, ask for assistance to
be performed by a manufacturer’s
technician.
Dust leaks from the vacuum cleaner Filters are broken Replace them with others of identical
type.
Inadequate lter Replace it with another of a suitable
category and check.
Electrostatic current on the vacuum
cleaner
Non existent or inefcient grounding Check all ground connections. In
particular on the vacuum inlet tting;
replace the hose with an antistatic
hose.