Specifications
Operating manual BDC3140 DBP/LPP 10/12
info@blastrac.eu
GB
HEPA lter replacement
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
WARNING!
Do not use the absolute lter again after having
removed it from the vacuum cleaner.
Figure 11
1. Vacuum cap
2. Locking lever
3. Safety bolt
4. Absolute lter lock ring
5. Absolute lter disc
6. Absolute lter
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
■ Unlock the safety bolt (3).
■ Use the lever (2) to release the cap (1) then pull it up
and out of the vacuum cleaner.
■ Unscrew ring (4).
■ Pull out disc (5) and absolute lter (6).
■ Place absolute lter (6) in a plastic bag, close the bag
hermetically and dispose of the lter in accordance with
the laws in force.
■ Insert a new lter (6) with the same ltering
characteristics as the removed one.
■ Lock the absolute lter with disc (5) and tighten ring (4).
■ Insert the cap (1) again.
■ Fix the cap in place with the lever (2) and lock the
safety bolt (3) again.
Motor cooling fan inspection and
cleaning
Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the vacuum cleaner is used in
a dusty place.
Tightness inspection
Figure 12
1. Suction connecting hose
2. Hose
■ Hoses check
Make sure that the suction connecting hose (1) is in a
good condition and correctly xed.
If the hose is damaged, broken or badly connected to
the unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose (2), in the inlet and on the
bafe plate inside the ltering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in the gure.
Figure 13
1. Seal
2. Screws
3. Filtering chamber
■ Filtering chamber tightness check
If the gasket (1) between the container and the ltering
chamber (3) fails to guarantee tightness:
▪ Loosen the four screws (2) that lock the ltering
chamber (3) against the vacuum cleaner structure.
▪ Allow the ltering chamber (3) to lower down and
tighten the screws (2) once it has reached the
tightness position.
The gasket (1) must be replaced if it is torn, cut, etc.
Disposing of the vacuum cleaner
Figure 14
Dispose of the vacuum cleaner in compliance with the laws
in force.
■ Proper disposal (electric and electronic waste).
(Applicable in the European Union and in
countries providing a separate collection system)
The above symbol (Fig. 14), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damage to the environment or health caused by
improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reutilisation of material resources.
This product can not be disposed of together with other
commercial waste.
Wiring diagrams
Figure 15 - 16
Item Part
Code of the model
230V/60Hz 400V/50Hz 440/60Hz
Q1 Main switch Z8 39989
Q2
Circuit
breaker
Z8 39535
Z8 39726
Z8 39916
Z8 39726
Z8 39014
Z8 39726
KM1 Contactor
Z8 39102
Z8 39838
Z8 39281 Z8 391105
TS2 Cyclic timer Z8 391107