User Manual

12
5) GAS CONNECTION
The gas connection is located in the rear and on the
underside of the appliance 100 mm from the right
hand side.
There are two ways to carry out the connection to
the main gas line:
A. The hotplate can be connected with rigid pipe as
specified in AS5601 table 3.1.
B. If installing with a hose assembly, install with a
hose assembly that complies with AS/ANZ 1869
(AGA Approved), 10mm ID, class B or D, no more
than 1.2m long and in accordance with AS5601.
Ensure that the hose does not contact the hot
surfaces of the hotplate, oven, dishwasher or any
other appliance that may be installed underneath or
next to the hotplate. The hose should not be
subjected to abrasion, kinking or permanent
deformation and should be able to be inspected
along its entire length with the cooktop in the
installed position.
Unions compatible with the hose fittings must be
used and all connections tested for gas leaks.
The gas supply connection for the hose assembly
must be accessible.
Warning: ensure that the hose assembly is
restrained from accidental contact with the flue or
flue outlet of an underbench oven.
Natural Gas
Natural Gas installations require the connection of
a gas regulator at the appliance. This regulator is
supplied with the appliance on purchase.
Assemble the regulator (noting the gas flow
direction) and transition pieces (supplied with the
appliance), in accordance with figure 6.
The transition piece on the supply side of the
regulator must be provided by the installer.
Liquified Petroleum Gas
In a Propane Gas installation the gas regulation is
made at the gas cylinder and regulation at the
appliance is not required. To connect supply to the
appliance use transition pieces as shown in
figure 7 . These pieces are supplied with the
appliance on purchase.
WARNING:
THE BURNER FLAME MUST BE ADJUSTED BY
THE INSTALLER.
FAULTY INSTALLATION WILL NOT BE
COVERED UNDER WARRANTY.
THE APPLIANCE IS FACTORY SET FOR
NATURAL GAS. THE TEST POINT PRESSURE
SHOULD BE ADJUSTED TO 1.00kPa WITH THE
WOK BURNER OPERATING AT MAXIMUM.
INSTALLATION
FIG. 6
FIG. 7