User Manual
CONVERSIONS
11
8) PROPANE GAS TO NATURAL GAS
CONVERSION PROCEDURE
Appliance  models:  Gas  stainless  steel  hotplate
models:
CG302FFX  2 Burners
CG604WXC 4 Burners
CG604WXFFC  4 Burners
CG604XP  4 Burners
CG604XFFP  4 Burners
CG604WXP  4 Burners
CG604WXFFP  4 Burners
CG705WXC  5 Burners
CG705WXFFC 5 Burners
1. Remove each burner cap and burner skirt.
2. Remove the Propane Gas main injector with a
7  mm/VF  tube  spanner  and  replace  with  the
appropriate  size  Natural  Gas  main  injector  for
each  burner.  The  following  injector  sizes  are
required for Natural Gas:
Burner Main injector
Wok 1.76 mm
Rapid 1.55 mm
Semi Rapid 1.20 mm
Auxiliary 0.90 mm
3. Shut off gas supply to the appliance.
4. Disconnect gas inlet pipe from the Propane Gas
test point inlet fitting.
5. Remove the Propane Gas test point inlet fitting
from the appliance.
6. Fit  the  Natural  Gas  Regulator  supplied  in  the
conversion kit.
7. Connect the gas supply to the Regulator.
8. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
9. Adjust  the  gas  pressure  to  1.00  kPa  with  the
wok burner operating on high flame.
10. Remove  the  control  knob,  with  a  thin  shaft
blade  screwdriver  inserted  on  the  left  side  of  the
gas  valve  shaft  (safety  valve  models)  or  down  in
the centre of the gas valve shaft (non-safety valve
models),  screw  the  by-pass  injector  anti-
clockwise. Test  the  appliance  on  both  high  and
low  flame  for  each  burner.  If  the  burner  fails  to
remain  alight  or  the  flame  is  not  stable  on  the
simmer  setting,  adjust  the  by-pass  screw,  until
flame is stable.
11.  If  not  already  removed,  remove  the  "Only  for
use  with  Propane  Gas"  label  adhered  to  the
bottom panel near the gas connection.
12.  Fit  the  new  data  label  included  in  the  gas
conversion kit.