Owner's manual
HG-CF-1119 Rev. F – 10.12.09 Page 11
Performance Curve
B15 Pump performance curve Performance based on waterat ambient temperature
Re-Assembly of Outer Covers
When re-assembling the pump after any service or maintenance work, both Outer Covers must be re-torqued using the sequence shown
above. The orientation of the pump is not important, providing the above sequence is followed. Failure to comply with these instructions
may result in poor sealing and mis-alignment between the diaphragm sealing faces.