Owner's manual
b75nmdl2sm-rev0713 Model B75 Non-Metallic Design Level 2 Page 34
2/07 Model B75 Non-Metallic Design Level 2 Page 31
Leak Detection Options Drawing
LEAK DETECTION OPTION (ELECTRONIC)
Follow instructions found elsewhere in this manual, “Filling the
Spill Prevention Chambers” when installing leak detectors.
Electronic Leak Detector Installation
Kit 032-037-000 100VAC 50Hz
or 110-120VAC 50/60Hz
or 220-240VAC 50/60Hz
Kit 032-045-000 12-32VDC
To install electronic leak detectors, remove the bottom ¼" NPT pipe
plug on the visual sight tube (item 52). Insert leak detector into the
¼" pipe tee (item 56).
LEAK DETECTION OPTION (MECHANICAL)
Follow instructions found elsewhere in this manual, “Filling
the Spill Prevention Chambers” when installing leak detectors.
Mechanical Leak Detector Installation
Kit 031-023-110
To install mechanical leak detectors, remove the bottom ¼" NPT
pipe plug on the visual sight tube (item 52). Insert leak detector into
the ¼" pipe tee (item 56).
For pumps with
530-028-550
ENCLOSED MUFFLER
For pumps with
ALTERNATE MUFFLERS
710-009-115
Self-tapping Screws
(Qty of 4)
612-185-552
Mounting Plate