Instruction manual
13
EN
North
4X
4X
e
d
c
b
a
e
d
c
b
a
e
d
c
b
a
e
d
c
b
a
Calibration Procedures
Compass calibration procedure:
NOTICE:Thefollowingprocedurehastobe
completedwithin30secondsafterenteringcompass
calibrationmode.
1.Powerthetransmitter.
2.Poweronthe350QX3andfacethe
quadcopterpointingNorth.
3.Cyclethetoplefttransmitterswitchcompletely
4timesasshownattheleft.
4.The350QX3indicatesithasenteredcompass
calibrationmodebyslowlyashingtheLEDorange.
5.WhentheLEDbeginstoashrapidly,complete
all4rotationsofthe350QX3asshowninthe
illustrationatleftwithin30seconds,rotatingthe
quad45°counterclockwisebetweeneachrotation.
6.Holdthequadlevel,facingNorthandchecktheLED.
Green = Ready
Red = Repeat Compass Calibration
Accelerometer calibration procedure:
1.Poweronthetransmitterand350QX3and
placethequadonaat,levelsurface.
2.Whileholdingthebindswitchonthetransmitter,
cyclethetopleftswitch4timesasshownattheleft.
3.The350QX3willemitaseriesofslowtones
followedbyaseriesofrapidtones,indicatingthe
calibrationhasstarted.
4.Donotmovethe350QX3whileitperformsthe
accelerometercalibrationprocedure.
5.Whentheprocedurehascompleted,the350QX3will
emita“happy”toneandtheLEDwilldisplaygreen
indicatingthecalibrationwassuccessful.Ifitemitsa
“sad”toneandtheLEDdisplayssolidred,repeatthe
calibrationprocedure.
Pressure Sensor Calibration
Thepressuresensoriscalibratedatthefactoryonthe
350QX3.Recalibrationshouldonlybenecessaryifyou
replacethesensor.
1.Placethe350QX3inacoldarea.Allowittoremain
inthecoldfor30minutesormore.
2.Bringthe350QX3outofthecoldandintoawarm
area.Thegreaterthedifferenceintemperature
betweenthecoldandwarmareas,themoreaccurate
thecalibrationwillbe.
3.Ensureyourtransmitterisoffandthenconnecta
ightbatterytothe350QX3Powerthe350QX3ON
andletitinitialize.ThestatusLEDwillremainoff.
4.Holdthe350QX3upsidedownuntilthestatusLED
ashesblue,indicatingithasenteredbindmode.
5.Setthequadcopterbackupright.
6.Bindyourtransmittertothe350QX3withtherudder
stickfullytotheright.TheLEDwillblinkredandblue
rapidly.Leavetheaircraftandtransmitterpowered
onandallowtheaircrafttowarmupfor10minutes.
Donotmovetheaircraftduringthistime.
7.After10minutesthemotorsontheaircraftwillbeep
toindicatethecalibrationiscomplete.Poweroffthe
aircraftandthenyourtransmitter.
Ifthe350QX3displaysthefailedcalibrationcode,power
offtheaircraftandthenbeginthepressurecalibration
procedureagain.
Rudderright
Bindinpressurecalibrationmode