Technical data

RackSwitch G8124 Command Reference
22
Chapter 1: ISCLI Basics BMD00076, January 2009
NOTEWith the exception of the “admin” user, access to each user level can be disabled by
setting the password to an empty value.
Idle Timeout
By default, the switch will disconnect your Telnet session after five minutes of inactivity. This
function is controlled by the following command, which can be set from 1 to 60 minutes:
system idle <1-60>
Command mode: Global Configuration
Table 1-3 User Access Levels
User Account Description and Tasks Performed Password
User The User has no direct responsibility for switch management.
He or she can view all switch status information and statistics,
but cannot make any configuration changes to the switch.
user
Operator Interaction with the switch is completely passive—nothing can
be changed on the switch. Users can display information that
has no security or privacy implications, such as switch statistics
and current operational state information. Users who have an
ID with oper privileges can make operational changes, such as
running operational-level commands to disable an interface.
Administrator
The superuser Administrator has complete access to all com-
mand modes, information, and configuration commands on the
switch, including the ability to change both the user and admin-
istrator passwords.
admin