RackSwitch™ G8124 Installation Guide Part Number: BPP-00018-01, December 2009 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.
RackSwitch G8124 Installation Guide Copyright © 2009 BLADE Network Technologies, Inc., 2350 Mission College Blvd., Suite 600, Santa Clara, California, 95054, USA. All rights reserved. Part Number: BPP-00018-01. This document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this document may be reproduced in any form by any means without prior written authorization of BLADE Network Technologies, Inc.
Contents Preface 5 Who Should Use This Book 5 Related Documentation 5 How to Get Help 6 Chapter 1: RackSwitch G8124 Description and Specifications RackSwitch G8124 Features 7 Performance 7 Management Features 7 Software Features 8 Switch Components 9 Hardware Options 9 Switch Unit 9 Switch Ports 12 LEDs 15 Technical Specifications 17 Physical Characteristics 17 Environmental Specifications 17 Power Specifications 18 Ordering Information 19 Chapter 2: Installing the RackSw
RackSwitch G8124 Installation Guide Initializing the RackSwitch G8124 32 Default Configuration 33 Configuring an IP Interface 34 Using the Boot Management Menu 35 Installing an SFP or SFP+ Transceiver 36 SFP+ Optical Transceiver 36 SFP Copper Transceiver 37 Troubleshooting 38 System LEDs Do Not Light 38 Port link LED Does Not Light 38 Temperature Sensor Warning 38 Switch Does Not Initialize (Boot) 39 Appendix A: Safety and Compliance Statements Safety Messages 41 Compliance Statem
Preface This Installation Guide provides information and instructions to install a BLADE Network Technologies RackSwitch G8124. For information about configuration and management of the switch, refer to the Command Reference and the product release notes. Who Should Use This Book This Installation Guide is intended for network installers and system administrators engaged in configuring and maintaining a network.
RackSwitch G8124 Installation Guide How to Get Help If you need help, service, or technical assistance, call Blade Network Technologies Technical Support: US toll free calls: 1-800-414-5268 International calls: 1-408-834-7871 You also can visit our web site at the following address: http://www.bladenetwork.net Click the Support tab. The warranty card received with your product provides details for contacting a customer support representative.
CHAPTER 1 RackSwitch G8124 Description and Specifications The RackSwitch G8124 is an all 10Gb Ethernet rackable aggregation switch with unmatched line-rate Layer 2 performance. The G8124 uses a wire-speed, non-blocking switching fabric that provides simultaneous wire-speed transport of multiple packets at low latency on all ports. The G8124 contains twenty-four 10Gb Small Form-factor, Pluggable (SFP+) slots and two 1Gb management ports.
RackSwitch G8124 Installation Guide Protocols SNMP v1, v2, v3 Secondary NTP support DHCP Software upgrades Dual software images Upgrade via serial, browser, or FTP/TFTP Software Features Security Secure interface login & password RADIUS and TACACS+ SSH v1, v2 HTTPS Secure Browser-based interface Wire-speed filtering with Access Control Lists (ACLs) Layer 2 1024 VLANs (802.
RackSwitch G8124 Installation Guide Switch Components This section describes the RackSwitch G8124 hardware components. Hardware Options The following list provides an overview of G8124 hardware: Switch unit Mounting hardware Standard rack mounting brackets and screws iDataPlex rack mounting brackets and screws 4-post rack mounting brackets and screws Switch Unit The RackSwitch G8124 switch unit is a 1U rack-mountable 10 Gigabit Ethernet switch.
RackSwitch G8124 Installation Guide Figure 1 RackSwitch G8124 Front Panel RJ-45 ports BLADE Rackswitch G8124 B SP L/A A MB MS Stacking 1 2 3 4 5 System status LEDs 6 7 8 9 10 11 12 13 14 15 16 17 18 SFP+ slots 19 20 21 22 23 24 10101 Reset RS-232 port Mgmt Reset button Figure 2 RackSwitch G8124 Rear Panel (AC) IEC 320 Power connector IEC 320 Power connector Figure 3 RackSwitch G8124 Rear Panel (DC) DC Power connector 10 Chapter 1: RackSwitch G8124 Description and Spe
RackSwitch G8124 Installation Guide Reset Button The Reset button is recessed within a hole on the front panel. Use a straightened paper clip or similar object to press the Reset button. The Reset button allows technicians to reset the switch, as follows: Press Reset: The switch resets and reloads the configuration files. Press and hold Reset for five seconds: The switch resets and configures all settings to factory defaults. Fans Six internal fans cool the switch unit.
RackSwitch G8124 Installation Guide DC Power Supply The DC Powered G8124 has two redundant 250W DC-DC power supplies, operating from 42V to 60V. Each internal power supply has a DC filter input on the rear panel. The DC power sources are connected to the G8124 via the mating connector cable assemblies provided. One end of the cable is connected to the G8124 and the three DC-input leads connect the DC-input power supply to the site power source.
RackSwitch G8124 Installation Guide Transceivers are not included with the G8124 switch unit.
RackSwitch G8124 Installation Guide Console Port The RS-232 (mini-USB) serial console port is located on the front panel. An external cable is required to convert to a D9 connector.
RackSwitch G8124 Installation Guide LEDs Two LED stacks provide system status and port link status.
RackSwitch G8124 Installation Guide XGE Port LEDs Figure 4 highlights the system LEDs and SFP+ port LEDs. Figure 4 System Status LEDs and Port LEDs BLADE Rackswitch G8124 SP L/A MB MS Stacking 1 2 3 4 Status and link LEDs for the data port slots are described in the following table.
RackSwitch G8124 Installation Guide Technical Specifications This section provides specifications for the RackSwitch G8124. Physical Characteristics Physical characteristics of the RackSwitch G8124F/G81240R switch unit are listed in the following table. Table 8 Physical Characteristics Specification G8124F G8124R Dimensions (H x W x D) 1.73 x 17.3 x 15.0 in. 1.73 x 17.3 x 15.0 in. 4.4 x 43.9 x 38.1 cm. 4.4 x 43.9 x 38.1 cm. Weight 6.4 kg. 6.4 kg.
RackSwitch G8124 Installation Guide Table 9 Environmental Specifications Specification Measurement Acoustic noise less than 65dB Heat dissipation 1100 BTU/hour (maximum) Power Specifications Power specifications for the RackSwitch G8124F/G8124R switch unit are listed in Table 10 and Table 11. Table 10 AC Power Specifications Specification Measurement Number of power supplies 2 (1+1 redundant) AC-input frequency (universal) 50-60 Hz AC-input voltage (universal) 100-240 VAC AC-input current 2.
RackSwitch G8124 Installation Guide Ordering Information The following table lists the parts that you can order for the RackSwitch G8124 product family.
RackSwitch G8124 Installation Guide 20 Chapter 1: RackSwitch G8124 Description and Specifications BPP-00018-01, December 2009
CHAPTER 2 Installing the RackSwitch G8124 This chapter describes how to install and initialize the RackSwitch G8124.
RackSwitch G8124 Installation Guide Environmental Requirements This section describes the basic environmental requirements for the RackSwitch G8124. Make sure the location where you install the switch meets the following requirements: Install the switch unit in a dry, clean, well-ventilated area. Provide adequate space on all sides of the switch unit, to ensure proper air flow. Make sure that an adequate grounded power supply is within reach of the switch unit.
RackSwitch G8124 Installation Guide Preventing Electrostatic Discharge Electrostatic discharge (ESD) is a discharge of stored static electricity that can damage equipment and impair electrical circuitry. ESD can cause intermittent or complete equipment failures. Use the following guidelines to prevent ESD damage while you install and work with the G8124 and optional equipment: Use anti-static wrist straps. Adjust the strap to provide good skin contact.
RackSwitch G8124 Installation Guide Caution—Do not stack other devices on top of the switch unit in the rack. The mounting brackets cannot support multiple devices. Use mounting brackets to secure each device to the rack. Perform the following steps to mount the RackSwitch G8124. 1. Use the M4 screws to attach a mounting bracket to each side of the switch. Torque the screws to approximately 30 inch-pounds (3.5 Nm).
RackSwitch G8124 Installation Guide 2. Slide the switch into the rack as illustrated. Figure 6 Rack-mounting the Switch Unit 3. Use M6 screws, washers, and clip nuts to secure the switch unit to the rack. Torque the screws to approximately 30 inch-pounds (3.5 Nm).
RackSwitch G8124 Installation Guide Installing the RackSwitch G8124 in an iDataPlex Rack This section provides general information about installing the RackSwitch G8124 in an IBM iDataPlex rack. The iDataPlex mounting kit allows the switch to be mounted either vertically or horizontally.
RackSwitch G8124 Installation Guide Perform the following steps to mount the RackSwitch G8124 into an iDataPlex rack. 1. Use the M4 screws to attach front and rear mounting brackets to each side of the switch unit. Torque the screws to approximately 30 inch-pounds (3.5 Nm).
RackSwitch G8124 Installation Guide 2. M6 screws, washers, and clip nuts are used to attach the alignment plate. Torque the screws to approximately 30 inch-pounds (3.5 Nm). Figure 8 Attaching the Alignment Plate 3. M6 screws, washers, and clip nuts are used to mount the switch unit into the rack. Torque the screws to approximately 30 inch-pounds (3.5 Nm).
RackSwitch G8124 Installation Guide Installing the RackSwitch G8124 in a 4-post Rack This section provides general information about installing the RackSwitch G8124 in a 4-post rack, including the IBM e1350 - Type 1410. For information about mounting the G8124 in other rack types, refer to the following sections: “Installing the RackSwitch G8124 in a Standard Equipment Rack” on page 23 “Installing the RackSwitch G8124 in an iDataPlex Rack” on page 26 The 4-post mounting kit is ordered separately.
RackSwitch G8124 Installation Guide Perform the following steps to mount the RackSwitch G8124 into a standard 4-post rack. 1. Use the M4 screws to attach a horizontal rail to each side of the switch. Torque the screws to approximately 10 inch-pounds (1.1 Nm). Figure 10 Attaching the Horizontal Rail 2. M6 screws, washers, and clip nuts are used to connect the horizontal rail to the front posts in the rack. Torque the screws to approximately 70 inch-pounds (8.0 Nm).
RackSwitch G8124 Installation Guide 3. The rear mounting brackets are secured to the rack with M6 screws, washers, and clip nuts. Torque the screws to approximately 30 inch-pounds (3.5 Nm). Figure 12 Attaching Rear Mounting Brackets 4. The front mounting brackets and the rear mounting brackets are secured with M3 screws. Torque the screws to approximately 4 inch-pounds (0.5 Nm).
RackSwitch G8124 Installation Guide Initializing the RackSwitch G8124 When you plug in the G8124 power cord, the switch initializes automatically. Caution—The G8124 does not have a power switch. When you connect the switch to a suitable power source, the switch powers up immediately. Disconnecting the switch from the power source is the only way to power down the G8124. Always provide the power source in a location that is quickly and safely accessible.
RackSwitch G8124 Installation Guide The switch performs initial self tests, and displays the Password: prompt, similar to the following screen: Memory Test ................................ Production Mode PPCBoot 0.0.0.10 (new flash) Memory Test (0x00) .............................PASSED ... Blade Network Technologies RS 8124 Jan 1 00:01:27 2008: NOTICE-5:Interface Oper Status Indication - Port 7 State UP Password: At the Password: prompt, enter the switch password, and press .
RackSwitch G8124 Installation Guide Configuring an IP Interface To manage the switch using Telnet, SNMP, or a Web browser, you must configure an IP interface. Configure the following IP parameters: IP address Subnet mask Gateway address 1. Log on to the switch. 2. Enter Global Configuration mode. RS G8124> enable RS G8124# configure terminal 3. Configure the management IP address, subnet mask, and gateway.
RackSwitch G8124 Installation Guide Using the Boot Management Menu The Boot Management menu allows you to switch the software image, reset the switch to factory defaults, or to recover from a failed software download. You can interrupt the boot process and enter the Boot Management menu from the serial console port. When the system displays Memory Test, press . The Boot Management menu appears. Resetting the System ... Memory Test ................................
RackSwitch G8124 Installation Guide Installing an SFP or SFP+ Transceiver The RackSwitch G8124 supports the following Small Form Factor Pluggable (SFP+) transceivers: SFP+ 10GBase-SR Short Range Transceiver (BN-CKM-SP-SR) SFP+ 10GBase-LR Long Range Optical Fiber Transceiver (BN-CKM-SP-LR) SFP 1000BASE-T Copper Transceiver (BN-CKM-S-T) SFP 1000BASE-T-SX Short Range Optical Transceiver (BN-CKM-S-SX) SFP+ Optical Transceiver The G8124 only accepts approved SFP+ transceivers.
RackSwitch G8124 Installation Guide SFP Copper Transceiver The SFP copper transceiver provides an RJ-45 connector that accepts a standard 10/100/1000Base-T (category 5) cable. Perform the following steps to install an SFP copper transceiver into a 1Gbps SFP slot on the G8124 switch unit. Note – To avoid damage to the cable or the SFP transceiver, do not connect the cable before you install the transceiver. 1. Remove the safety cap and pull the locking lever into the down (unlocked) position. 2.
RackSwitch G8124 Installation Guide Troubleshooting This section contains basic troubleshooting information. Use it to help resolve problems that may occur during installation and operation of your switch. If you have problems accessing the switch or working with switch software, refer to your RackSwitch G8124 Application Guide or Command Reference. If you need additional technical assistance, refer to “How to Get Help” on page 6.
RackSwitch G8124 Installation Guide Switch Does Not Initialize (Boot) Symptom: All the switch LEDs stay on, and the command prompt does not appear on the console. Solution: The operating system may have been damaged. Use the console port to perform a serial upgrade of the switch software. Refer to your Command Reference.
RackSwitch G8124 Installation Guide 40 Chapter 2: Installing the RackSwitch G8124 BPP-00018-01, December 2009
APPENDIX A Safety and Compliance Statements Safety Messages This section lists the safety messages that appear within this manual. Caution—To reduce the risk of electric shock, use only power cords that have a grounding path, and always connect the power cord to a properly grounded power outlet. ATTENTION—Pour réduire le risque de décharge électrique, employez seulement les cordons de secteur qui ont un chemin fondant, et reliez toujours le cordon de secteur à une sortie correctement au sol de puissance.
RackSwitch G8124 Installation Guide Warning—Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. Connect the power supply only to a properly wired and grounded power source. Connect to properly wired outlets any equipment that will be attached to this product.
RackSwitch G8124 Installation Guide Advertencia—La corriente eléctrica de la energía, del teléfono, y de los cables de la comunicación es peligrosa. Para evitar un peligro de la descarga eléctrica: No conecte ni desconecte ninguna cables o no realice la instalación, el mantenimiento, o la reconfiguración de este producto durante una tormenta eléctrica. Conecte la fuente de alimentación solamente con una fuente de energía correctamente atada con alambre y puesta a tierra.
RackSwitch G8124 Installation Guide Caution—Do not stack other devices on top of the switch unit in the rack. The mounting brackets cannot support multiple devices. Use mounting brackets to secure each device to the rack. ATTENTION—Ne posez aucun appareil supplémentaire sur le commutateur sans support additionnel. Les supports ne peuvent soutenir plusieurs appareils. Utilisez les supports métalliques pour fixer chaque appareil aux armatures de la baie.
RackSwitch G8124 Installation Guide Caution—Class 1 Laser Product Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes. Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
RackSwitch G8124 Installation Guide Compliance Statements This section contains regulatory compliance statements for the RackSwitch G8124. Blade Network Technologies Commitment to WEEE The EU Directive of the EU Parliament and Council on Waste Electrical and Electronic Equipment (WEEE) became effective on 13 August 2005. Individual EU Member State implementations were made effective, or will be effective, during 2005 and 2006.
RackSwitch G8124 Installation Guide Industry Canada Class A Emission Compliance Statement This Class A digital apparatus complies with Canadian ICES-003. Avis de conformité à la réglementation d’Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Australia and New Zealand Class A Statement Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
RackSwitch G8124 Installation Guide NOM Statement (Mexico only) The following information is provided on the devices described in this document in compliance with the safety requirements of the Norma Oficial Méxicana (NOM): Exporter: Blade Network Technologies 2350 Mission College Blvd. Santa Clara, CA, 95054 USA Importer: IMPORSYS, S.A. de C.V.28 de Diciembre No. 22 Col. Avante, C.P. 04460 México, D.F. Input: RackSwitch G8124 G8124F AC 100-240 V~ 1.
RackSwitch G8124 Installation Guide Japanese Voluntary Control Council for Interference (VCCI) Statement Denan Statement (Japan/Nippon only) 本製品を安全にご使用いただくため、以下のことにご注意ください。 • 接続ケーブル、電源コード、AC アダプタなどの部品は、必ず製品に同梱されている添 付品または指定品をご使用ください。添付品・指定品以外の部品をご使用されることは 動作不良、火災の原因となることがあります。 • 同梱されております付属の電源コードを他の機器には使用しないでください。本注意 事項を守らないと、死亡や大怪我など人身事故の原因となることがあります。 KCC/MIC Notice (Republic of Korea only) This device has been approved for use in Business applications only per the Class A requirements of the Republic o
RackSwitch G8124 Installation Guide Toxic / Hazardous Substances and Elements Table (RackSwitch G8124F/G8124R) o: Indicates that the content of the toxic and hazardous substance in all the homogeneous materials of the part is below the concentration limit requirement as described in SJ/T 11363-2006. x: Indicates that the content of the toxic and hazardous substance in at least one homogeneous material of the part exceeds the concentration limit requirement as described in SJ/T 11363-2006.
RackSwitch G8124 Installation Guide BPP-00018-01, December 2009 Appendix A: Safety and Compliance Statements 51
RackSwitch G8124 Installation Guide 52 Appendix A: Safety and Compliance Statements 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.