Technical data
BLADE OS Command Reference
46
The Information Menu BMD00127, September 2009
/info/sys/general
General System Information
NOTE – The display of temperature will come up only if the temperature of any of the sensors
exceeds the temperature threshold. There will be a warning from the software if any of the sen-
sors exceeds this temperature threshold. The switch will shut down if the power supply over-
heats.
System information includes:
System date and time
Switch model
Switch name and location
Time of last boot
MAC address of the switch management processor
IP address of IP interface 128
Blade Network Technologies Rack Switch G8000
System Information at
Sun Jan 15 23:56:24 2009
Switch has been up for 0 day, 0 hour, 19 minutes and 31 seconds
Last boot:(power cycle)
MAC address: 00:18:b1:8a:36:00 IP (If 1) address: 172.24.1.70
Revision: 8
Switch Serial No: US38200028
Spare Part No: BAC-00017-00
Manufacturing date: 08/20
Software Version 6.0.1 (FLASH image2), active configuration.
Fans are in Forward AirFlow, Warning at 55 C and Recover at 80 C
Temperature Sensor 1: 32.0 C
Temperature Sensor 2: 38.0 C
Temperature Sensor 3: --.-
Temperature Sensor 4: 31.0 C
Speed of Fan 1: 0 RPM
Speed of Fan 2: 0 RPM
Speed of Fan 3: 0 RPM
Speed of Fan 4: 4224 RPM
Speed of Fan 5: 6272 RPM
State of Power Supply 1: On
State of Power Supply 2: Off