The Configuration Menu BMD00127, September 2009
/cfg/l2/failovr/trigger/mmon/monitor
Manual Monitor-Monitor Configuration
[Monitor Menu]
addport - Add port to Monitor
remport - Remove port from Monitor
addtrnk - Add trunk to Monitor
remtrnk - Remove trunk from Monitor
addkey - Add LACP port adminkey to Monitor
remkey - Remove LACP port adminkey from Monitor
cur - Display current Monitor configuration
Table 6-46 Manual Monitor-Monitor options (/cfg/l2/failovr/trigger/mmon/monitor)
Command Syntax and Usage
addport <port number>
Adds the selected port to the Manual Monitor - Monitor.
remport <port number>
Removes the selected port from the Manual Monitor - Monitor.
addtrnk <trunk number)>
Adds a trunk group to the Manual Monitor - Monitor.
remtrnk <trunk number>
Removes a trunk group from the Manual Monitor - Monitor.
addkey <1-65535>
Adds an LACP admin key to the Manual Monitor - Monitor. LACP trunks formed with
this admin key will be included in the Manual Monitor - Monitor.
remkey <1-65535>
Removes an LACP admin key from the Manual Monitor - Monitor.
cur
Displays the current Manual Monitor - Monitor configuration.