Specifications

Chapter 6. IBM Virtual Fabric 10Gb Switch Module implementation 247
5. Physically connect the stack trunks.
Connect the stacking links (Figure 6-1) and verify that the link is up.
Figure 6-1 Stack links physical connections
6. Verify the stacking configuration.
Verify the saved stacking configuration by running show boot stack (Example 6-5).
Example 6-5 Verify the stacking configuration
ACC-3#show boot stack
Current stacking settings:
Stacking : OFF
Switch Mode : n/a
Stack Trunk Ports: empty
Stack VLAN : 4090
Stacking settings saved:
Stacking : ON
Switch Mode : Master
Stack Trunk Ports: EXT9 EXT10
Stack VLAN : 4090
ACC-3#
ACC-4#show boot stack
Current stacking settings:
Stacking : OFF
Switch Mode : n/a
Stack Trunk Ports: empty
Stack VLAN : 4090
Stacking settings saved:
Stacking : ON