Chapter 5. IBM System Networking RackSwitch implementation 235
15 15 1G/10G full no no down
16 16 10000 full no no up
17 17 1G/10G full no no down
18 18 1G/10G full no no down
19 19 1G/10G full no no down
20 20 1G/10G full no no down
21 21 1G/10G full no no down
22 22 1G/10G full no no down
23 23 1G/10G full no no down
24 24 10000 full no no up
MGTA 25 1000 full yes yes up
MGTB 26 any any yes yes up
ACC-1#
d. Enable the two uplink ports.
Run no shutdown to manually enable the ports and see the messages related to the
failover operation (Example 5-89).
Example 5-89 Manually enable the ports
ACC-1#configure terminal
Enter configuration commands, one per line. End with Ctrl/Z.
ACC-1(config)#
ACC-1(config)#interface port 1,2
ACC-1(config-if)#no shutdown
ACC-1(config-if)#
Aug 11 13:00:57 ACC-1 NOTICE link: link up on port 1
Aug 11 13:00:58 ACC-1 NOTICE link: link up on port 2
Aug 11 13:00:58 ACC-1 NOTICE failover: Trigger 1 is up, control ports are
auto controlled.
Aug 11 13:01:03 ACC-1 NOTICE link: link up on port 7
ACC-1(config-if)#^Z
ACC-1#
e. Verify the Failover Trigger status.
Run show failover trigger <1-8> information to verify the Failover Trigger status
(Example 5-90).
Example 5-90 Verify the Failover Trigger status
ACC-1#show failover trigger 1 information
Trigger 1 Manual Monitor: Enabled
Trigger 1 limit: 2
Monitor State: Up
Member Status
--------- -----------
PortChannel 1
1 Operational