Specifications
142 Implementing IBM System Networking 10Gb Ethernet Switches
You may change the default TCP port number used to listen to LDAP (optional)
(Example 4-51). The known port for LDAP is 389.
Example 4-51 LDAP port
>> # ldap-server port <1-65000>
Configure the number of retry attempts for contacting the LDAP server, and the timeout
period (Example 4-52).
Example 4-52 LDAP retry and timeout
>> # ldap-server retransmit 3
>> # ldap-server timeout 10
4.4 First boot of the Virtual Fabric 10Gb Switch Module
embedded switch
If the switch is the embedded model inside the BladeCenter chassis, the initial boot and setup
is different. The management interfaces are accessible from the Advanced Management
Module (AMM) of the BladeCenter chassis. You should first log on to the AMM and then
configure the I/O modules that correspond to the switches you want to configure. During this
section, we describe this process and use the web interface. The CLI is also available from a
Telnet session, but using it is similar to the procedure described in 4.3, “First boot of the
RackSwitch G8264 switch” on page 127.