Failover Manual Monitor - Monitor Configuration
Use this menu to define the port link(s) to monitor. The Manual Monitor - Monitor configura-
tion accepts only external uplink ports.
Table 4-42 Failover Manual Monitor - Monitor commands
Command Syntax and Usage
failover trigger <1-8> mmon monitor member <port number>
Adds the selected port to the Manual Monitor - Monitor.
Command mode: Global configuration
no failover trigger <1-8> mmon monitor member <port number>
Removes the selected port from the Manual Monitor - Monitor.
Command mode: Global configuration
failover trigger <1-8> mmon monitor portchannel <trunk number>
Adds the selected trunk group to the Manual Monitor - Monitor.
Command mode: Global configuration
no failover trigger <1-8> mmon monitor portchannel <trunk number>
Removes the selected trunk group to the Manual Monitor - Monitor.
Command mode: Global configuration
failover trigger <1-8> mmon monitor adminkey <1-65535>
Adds an LACP admin key to the Manual Monitor - Monitor. LACP trunks formed with
this admin key will be included in the Manual Monitor - Monitor.
Command mode: Global configuration
no failover trigger <1-8> mmon monitor adminkey <1-65535>
Removes an LACP admin key from the Manual Monitor - Monitor.
Command mode: Global configuration