Technical data
BLADE OS 5.0 Command Reference
68
Chapter 4: The Information Menu BMD00142, November 2009
/info/l2/hotlink
Hot Links Information
/info/l2/hotlink/trigger
Hotlinks Trigger Information
Hot Links trigger information includes the following:
Hot Links status (on or off)
Status of BPDU flood option
Status of FDB send option
Status and configuration of each Hot Links trigger
[Hot Links Info Menu]
trigger - Show Trigger information
Table 21 Hot Links Information Options
Command Syntax and Usage
trigger
Displays status and configuration information for each Hot Links trigger.
To view a sample display, see page 68.
Hot Links Info: Trigger
Current global Hot Links setting: ON
bpdu disabled
sndfdb disabled
Current Trigger 1 setting: enabled
name "Trigger 1", preempt enabled, fdelay 1 sec
Active state: None
Master settings:
port 1
Backup settings:
port 2