Technical data

BLADE OS 5.0 Command Reference
BMD00142, November 2009 Chapter 4: The Information Menu
67
/info/l2/failovr/trigger <trigger number>
Show Layer 2 Failover Information
A monitor port’s Failover status is Operational only if all the following conditions hold true:
Port link is up.
If Spanning-Tree is enabled, the port is in the Forwarding state.
If the port is a member of an LACP trunk group, the port is aggregated.
If any of the above conditions are not true, the monitor port is considered to be failed.
A control port is considered to be operational if the monitor trigger state is Up. Even if a port’s link
status is Down, Spanning-Tree status is Blocking, and the LACP status is Not Aggregated,
from a teaming perspective the port status is Operational, since the trigger is Up.
A control ports status is displayed as Failed only if the monitor trigger state is Down.
Trigger 1 Auto Monitor: Enabled
Trigger 1 limit: 0
Monitor State: Up
Member Status
--------- -----------
trunk 1
2 Operational
3 Operational
Control State: Auto Disabled
Member Status
--------- -----------
1 Operational
2 Operational
3 Operational
4 Operational
...