Technical data
BLADE OS 5.0 Command Reference
BMD00142, November 2009 Chapter 3: Menu Basics
39
verbose n Sets the level of information displayed on the screen:
0 = Quiet: Nothing appears except errors—not even prompts.
1 = Normal: Prompts and requested output are shown, but no menus.
2 = Verbose: Everything is shown.
When used without a value, the current setting is displayed.
telnet This command is used to telnet out of the switch. The format is as follows:
telnet <hostname>|<IP address> [<port>] [-ma|-mgta|
-mb|-mgtb|-d|-data]
Where IP address is the hostname or IP address of the device. By default,
the -ma or -mgta option for management port A is used. To use data
ports, specify the -d or -data option.
history This command displays the most recent commands.
pushd Save the current menu path, so you can jump back to it using popd.
popd Go to the menu path and position previously saved by using pushd.
who Displays a list of users that are logged on to the switch.
chpass_p Configures the password for the primary TACACS+ server.
chpass_s Configures the password for the secondary TACACS+ server.
Table 3 Description of Global Commands
Command Action