Chapter 6: The Configuration Menu BMD00142, November 2009
count <1-10>
Configures the Startup Query Count, which is the number of IGMP Queries sent out at
startup. Each Query is separated by the Startup Query Interval.
sinter <1-608>
Configures the Startup Query Interval, which is the interval between General Queries sent out
at startup.
version [v1|v2|v3]
Configures the IGMP version.
on
Globally turns IGMP Querier on.
off
Globally turns IGMP Querier off.
default
Resets IGMP Querier parameters to default values.
cur
Displays the current IGMP Querier parameters.
Table 174 IGMP Querier Options