Technical data
BLADE OS 5.0 Command Reference
244
î‚„ Chapter 6: The Configuration Menu BMD00142, November 2009
/cfg/l2/failovr/trigger/mmon/control
Manual Monitor Control Configuration
Use this menu to define the port link(s) to control.
The Manual Monitor–Control configuration accepts internal and external ports, but not
management ports.
[Control Menu]
addport - Add port to Control
remport - Remove port from Control
addtrnk - Add trunk to Control
remtrnk - Remove trunk from Control
addkey - Add LACP port adminkey to Control
remkey - Remove LACP port adminkey from Control
cur - Display current Control configuration
Table 138 Failover Manual Monitor - Control Options
Command Syntax and Usage
addport <port alias or number>
Adds the selected port to the Manual Monitor - Control.
remport <port alias or number>
Removes the selected port from the Manual Monitor - Control.
addtrnk <trunk number>
Adds a trunk group to the Manual Monitor - Control.
remtrnk <trunk number>
Removes a trunk group from the Manual Monitor - Control.
addkey <1-65535>
Adds a LACP admin key to the Manual Monitor - Control. LACP trunks formed with this
admin key will be included in the Manual Monitor - Control.
remkey <1-65535>
Removes a LACP admin key from the Manual Monitor - Control.
cur