Technical data

BLADE OS 5.0 Command Reference
BMD00142, November 2009 Chapter 6: The Configuration Menu
243
/cfg/l2/failovr/trigger/mmon/monitor
Manual Monitor Port Configuration
Use this menu to define the port link(s) to monitor. The Manual Monitor - Monitor configuration
accepts only external uplink ports.
[Monitor Menu]
addport - Add port to Monitor
remport - Remove port from Monitor
addtrnk - Add trunk to Monitor
remtrnk - Remove trunk from Monitor
addkey - Add LACP port adminkey to Monitor
remkey - Remove LACP port adminkey from Monitor
cur - Display current Monitor configuration
Table 137 Failover Manual Monitor - Monitor Options
Command Syntax and Usage
addport <port alias or number>
Adds the selected port to the Manual Monitor - Monitor.
remport <port alias or number>
Removes the selected port from the Manual Monitor - Monitor.
addtrnk <trunk number>
Adds a trunk group to the Manual Monitor - Monitor.
remtrnk <trunk number>
Removes a trunk group from the Manual Monitor - Monitor.
addkey <1-65535>
Adds a LACP admin key to the Manual Monitor - Monitor. LACP trunks formed with this
admin key will be included in the Manual Monitor - Monitor.
remkey <1-65535>
Removes a LACP admin key from the Manual Monitor - Monitor.
cur
Displays the current Manual Monitor - Monitor configuration.