Technical data

BLADEOS 6.3 Command Reference
390
Chapter 4: Configuration Commands BMD00186-B, April 2010
Remote Monitoring Configuration
Remote Monitoring (RMON) allows you to monitor traffic flowing through the switch. The RMON
MIB is described in RFC 1757.
The following sections describe the Remote Monitoring (RMON) configuration options.
“RMON History Configuration” on page 390
“RMON Event Configuration” on page 391
“RMON Alarm Configuration” on page 392
RMON History Configuration
Table 249 describes the RMON History commands.
Table 249 RMON History commands
Command Syntax and Usage
rmon history <1-65535> interface-oid <1-127 characters>
Configures the interface MIB Object Identifier. The IFOID must correspond to the standard
interface OID, as follows:
1.3.6.1.2.1.2.2.1.1.x
where x is the ifIndex
Command mode: Global configuration
rmon history <1-65535> requested-buckets <1-65535>
Configures the requested number of buckets, which is the number of discrete time intervals
over which data is to be saved. The default value is 30.
The maximum number of buckets that can be granted is 50.
Command mode: Global configuration
rmon history <1-65535> polling-interval <1-3600>
Configures the time interval over which the data is sampled for each bucket.
The default value is 1800.
Command mode: Global configuration