Technical data
BLADEOS 6.3 Command Reference
292
Chapter 4: Configuration Commands BMD00186-B, April 2010
Failover Trigger Configuration
Failover Manual Monitor Port Configuration
Use these commands to define the port link(s) to monitor. The Manual Monitor Port configuration
accepts any non-management port.
Table 176 Failover Trigger Configuration Commands
Command Syntax and Usage
[no] failover trigger <1-8> enable
Enables or disables the Failover trigger.
Command mode: Global configuration
no failover trigger <1-8>
Deletes the Failover trigger.
Command mode: Global configuration
failover trigger <1-8> limit <0-1024>
Configures the minimum number of operational links allowed within each trigger before the
trigger initiates a failover event. If you enter a value of zero (0), the switch triggers a failover
event only when no links in the trigger are operational.
Command mode: Global configuration
show failover trigger <1-8>
Displays the current failover trigger settings.
Command mode: All except User EXEC
Table 177 Failover Manual Monitor Port commands
Command Syntax and Usage
failover trigger <1-8> mmon monitor member <port alias or number>
Adds the selected port to the Manual Monitor Port configuration.
Command mode: Global configuration
no failover trigger <1-8> mmon monitor member <port alias or number>
Removes the selected port from the Manual Monitor Port configuration.
Command mode: Global configuration